Your Trusted Microsphere Manufacturer for Diagnostic Innovation

Microspheres for IVD & POCT Assay Development

Colored, fluorescent, time-resolved fluorescent and functionalized microspheres for lateral flow, immunodiagnostics, flow cytometry and point-of-care testing.

Colored, Fluorescent and Functional Microspheres

Custom Particle Size, Color and Surface Chemistry

Support from Assay Development to Commercial Production

Technical Recommendation Within 24 Hours

Microspheres

Need help selecting a bead?

Share two details for a tailored starting point.

PRODUCT PLATFORM

Choose the Right Microsphere for Your Diagnostic Platform

Colored Microspheres

Colored Microspheres

Polystyrene (PS), PMMA, Silica, Spacer Microspheres



Application
Visual LFIA、rapid diagnostic test strips、qualitative/semi-quantitative detection、multiplex colorimetric assays
Green-fluorescent microspheres-4

Fluorescent Microspheres

High-brightness internally dyed microspheres for sensitive and quantitative detection.



Application
Fluorescent LFIA、quantitative POCT、immunofluorescence、reader-based detection


Rare-Earth-Time-Resolved-Fluorescent-Microspheres-(TRFM)

Time-Resolved Fluorescent Microspheres

Long fluorescence lifetime and reduced background interference for high-sensitivity assays.

Application
High-sensitivity LFIA、quantitative immunoassays、low-background detection、europium systems

Explore TRF Microspheres

Streptavidin-Magnetic-Beads

Streptavidin & Functional Microspheres

Streptavidin, carboxyl, amino, epoxy and custom surface options for biomolecule coupling.


Application
Biotinylated antibodies/antigens、nucleic acid assays、bead immunoassays、multiplex assays


Explore Functional Microspheres

Flow-Cytometry

Flow Cytometry & Specialty Microspheres

Consistent particle concentration and fluorescence options for calibration and quantitative analysis.

Application
Absolute counting、instrument calibration、multiplex detection、specialty diagnostic applications

Discuss Your Application

PRODUCT PLATFORM

Microsphere Solutions by IVD & POCT Application

Start with your binding principle. Then confirm particle size, buffer, solids content and workflow requirements with our technical team.

Bring the assay context. Narrow the particle starting point.

We offer a diverse range of precision-engineered solutions, from advanced chromatography media to magnetic beads and fluorescent microspheres, empowering industries worldwide.

PRODUCT SPECIFICATIONS

Compare Microsphere Options for Your Assay

Assay PlatformRecommended MicrosphereDetection ModeSurfaceMain Benefit
Visual LFIAColored Carboxyl MicrospheresVisualCOOHStrong test-line contrast
Quantitative LFIAFluorescent MicrospheresFluorescence readerCOOH / SAHigher sensitivity
High-Sensitivity LFIATime-Resolved Fluorescent MicrospheresTRF readerCOOHLow background signal
LTIAWhite Carboxyl PS MicrospheresTurbidimetryCOOHStrong light scattering
Latex AgglutinationPlain or Colored MicrospheresVisual / agglutinationPlain / COOHRapid qualitative detection
Flow CytometryFluorescent or Counting MicrospheresFlow cytometerPlain / functionalCalibration and quantification
Biotin-Based AssaysStreptavidin MicrospheresOptical / fluorescentStreptavidinHigh-affinity biotin capture
Assay PlatformRecommended MicrosphereDetection ModeSurfaceMain Benefit

DEFINE THE PARAMETERS

Custom Microspheres for Your Diagnostic Assay

SHBC provides microsphere solutions for IVD and POCT assay development, with support for product selection, customization, evaluation and scale-up supply.

Particle size

Influences migration, optical behavior, light scattering, surface area and assay response. State the target range or let the application guide the starting point.

Surface chemistry

Choose plain, carboxyl, amino, streptavidin or another confirmed functional route based on the biomolecule and immobilization method.

Signal modality

Match visible color, conventional fluorescence, time-resolved fluorescence or counting particles to the required readout and instrument.

Formulation

Solid content, concentration, buffer, dispersion, storage and suspension stability affect how a particle enters the development workflow.

Coupling approach

Share the antibody, antigen, protein or biotin workflow so the surface route and development sample can be aligned.

Custom Microspheres for Your Diagnostic Assay

Configure the material around your platform, from early screening to repeatable production. Availability is confirmed against the actual project requirement.

Particle Material

Polystyrene, PMMA and verified custom polymers

Particle Size

Nanometer-to-micrometer options within actual production capability

Color

Red, blue, black and verified custom visible colors

Fluorescence

Available excitation/emission channels and spectrum data

Surface Chemistry

Plain, carboxyl, amino, streptavidin and verified custom groups

Solid Content

Standard or customized concentration

Buffer

Standard or customer-specified buffer where feasible

Packaging

R&D samples, pilot quantities and bulk supply

Conjugation Support

Support for antibody, antigen, protein and other biomolecule conjugation workflows

CUSTOM

From Assay Development to Commercial Production

01

Application Review

Share the platform, target analyte, detection mode, reader parameters and sensitivity goal.

02

Microsphere Recommendation

Review the signal system, particle size, surface, color or channel and coupling route.

03

Sample Evaluation

Evaluate candidate samples with technical data and initial conjugation guidance.

04

Scale-Up & Bulk Supply

Move into pilot work, consistency review, packaging and long-term bulk supply.

OUR ADVANTAGES

Why IVD Developers Choose SHBC

Complete-Microsphere-Product-Portfolio

Complete Microsphere Product Portfolio

Full range of microspheres for IVD, POCT, and bioseparation.
IVD-and-POCT-Application-Experience

IVD and POCT Application Experience

Proven expertise in diagnostic and point-of-care applications.
Custom-Surface-Chemistry

Custom Surface Chemistry

Functional groups tailored for biomolecule binding.
Stable-Particle-Size-Distribution

Stable Particle Size Distribution

Precise size control ensures reliable assay performance.
Batch-to-Batch Consistency

Batch-to-Batch Consistency

Stable quality across all production batches.
OEM-and-Scale-Up-Manufacturing

OEM and Scale-Up Manufacturing

From lab development to industrial-scale manufacturing.

Quality information for development and transfer

Available records depend on product type and configuration. Confirm the documentation set required by your development, purchasing and quality teams.

Download Product Catalogue

Particle and formulation

Particle size and distribution report
Appearance, dispersion and suspension stability
Solid content / concentration
Storage conditions and shelf life

Surface and signal

Surface functional group or carboxyl content where applicable
Fluorescence excitation and emission spectrum where applicable

Batch and safety

Batch number and traceability
Safety Data Sheet (SDS)
Certificate of Analysis (COA)
Available quality-system and technical documentation

FREQUENTLY ASKED QUESTIONS

Microspheres For IVD & POCT Frequently Asked Questions

  • What types of microspheres are available for IVD and POCT assays?

    加 Created with Sketch.
    形状 Created with Sketch.

    SHBC offers colored microspheres, fluorescent microspheres, time-resolved fluorescent microspheres, carboxyl polystyrene microspheres, streptavidin microspheres and specialty counting microspheres for different IVD and POCT platforms.

  • Which microspheres are recommended for lateral flow assays?

    加 Created with Sketch.
    形状 Created with Sketch.

    Colored carboxyl microspheres are suitable for visual detection, while fluorescent and time-resolved fluorescent microspheres are suitable for reader-based and higher-sensitivity assays.

  • What is the difference between colored and fluorescent microspheres?

    加 Created with Sketch.
    形状 Created with Sketch.

    Colored microspheres provide a visible optical signal for qualitative or semi-quantitative detection, while fluorescent microspheres require a compatible fluorescence reader and are more suitable for quantitative or higher-sensitivity detection.

  • Can the particle size and surface carboxyl density be customized?

    加 Created with Sketch.
    形状 Created with Sketch.

    Yes. Particle size, solid content, surface functionality, carboxyl level, color and packaging can be customized depending on project requirements and production feasibility.

  • Which microspheres are suitable for EDC/NHS antibody coupling?

    加 Created with Sketch.
    形状 Created with Sketch.

    Carboxyl-functionalized microspheres are suitable for EDC/NHS activation and covalent coupling with amine-containing biomolecules such as antibodies and proteins.

  • Do you provide streptavidin-coated microspheres?

    加 Created with Sketch.
    形状 Created with Sketch.

    Yes. Streptavidin-functionalized microspheres are available for biotin-based capture and assay development.

  • Can you recommend microspheres based on our fluorescence reader?

    加 Created with Sketch.
    形状 Created with Sketch.

    Yes. Please provide the excitation and emission channels of your reader, and our technical team can recommend compatible fluorescent microsphere options.

  • Do you provide samples for assay evaluation?

    加 Created with Sketch.
    形状 Created with Sketch.

    Yes. Evaluation samples may be available depending on the product type and specification. Please contact us with your target application and required size.

  • What documentation is available with each batch?

    加 Created with Sketch.
    形状 Created with Sketch.

    Available documentation may include COA, SDS, particle size data, solid content, surface information and fluorescence spectrum data, depending on the product type.

  • Can you support pilot production and commercial-scale supply?

    加 Created with Sketch.
    形状 Created with Sketch.

    Yes. SHBC supports R&D evaluation, pilot-scale supply, OEM/ODM and bulk production for qualified projects.