Products
SHBC provides colored microspheres, fluorescent microspheres, magnetic beads, silica microspheres, chromatography packing microspheres and biological reagents for diagnostic assay development, nucleic acid extraction, protein purification and separation applications.
-
SPS40-10
-
SHBC
-
5%
-
40nm
-
10ml,20ml,50ml ,500ml,1000ml
40nm Standard Polystyrene Microspheres SPS40-10
SHBC SPS40-10 are uniform 40nm polystyrene nanoparticles supplied as a 5% solids suspension.
The microspheres are suitable for particle-size measurement research, instrument performance verification, microscopy studies, colloidal analysis and nanomaterial development.
Product Specifications
Item | Specification |
|---|---|
Product Name | Standard Polystyrene Microspheres |
Catalog Number | SPS40-10 |
Brand | SHBC |
Nominal Particle Size | 40nm |
Equivalent Particle Size | 0.04µm |
Solids Content | 5% |
Material | Polystyrene |
Product Form | Microsphere Suspension |
Manufacturer | Shanghai SanYu Biotechnology Co., Ltd. |
Key Product Advantages
Uniform nominal 40nm particle size
High 5% solids content
Spherical polystyrene nanoparticles
Good suspension and dilution flexibility
Suitable for nanoparticle measurement research
Compatible with multiple characterization methods
Research samples and bulk quantities available
Custom concentration and packaging supported
Why Choose 40nm Polystyrene Microspheres?
The 40nm particle size is suitable for studying the lower measurement range of nanoparticle characterization systems.
The 5% solids suspension provides sufficient material for:
Serial dilution
Repeated testing
Method optimization
Dispersion studies
Laboratory quality control
Pilot-scale research
Industrial development
Particle Size Measurement Research
SPS40-10 can be evaluated for particle-size analyzer performance verification and analytical method development.
Potential applications include:
Dynamic light scattering
Laser light scattering
Nanoparticle size analysis
Measurement repeatability testing
System suitability evaluation
Inter-instrument comparison
Sample preparation optimization
Final results may be influenced by concentration, dispersing medium, temperature, viscosity and instrument settings.
Dynamic Light Scattering Applications
The microspheres can be used for DLS method development and routine performance checks.
Users should optimize:
Dilution ratio
Sample concentration
Dispersing medium
Measurement temperature
Refractive-index settings
Medium viscosity
Measurement duration
Data-analysis model
The DLS hydrodynamic diameter may differ from the particle diameter measured by electron microscopy.
Electron Microscopy
SPS40-10 can be evaluated for:
Transmission electron microscopy
Scanning electron microscopy
Nanoparticle imaging
Particle morphology observation
Image-analysis development
Magnification and scale evaluation
Appropriate sample preparation is required to reduce aggregation and drying artifacts.
Atomic Force Microscopy
The 40nm polystyrene microspheres may be used in AFM research involving:
Nanoscale particle imaging
Surface-height measurement
Probe-response evaluation
Particle deposition studies
Image-analysis method development
The substrate and deposition method should be optimized for the application.
Colloid and Dispersion Research
SPS40-10 can be used as a model polymer nanoparticle in liquid-system research.
Potential applications include:
Colloidal stability
Particle aggregation
Salt-induced destabilization
Surfactant evaluation
Surface adsorption
Dispersion formulation
Particle–particle interactions
Particle–surface interactions
Filtration and Membrane Research
The 40nm microspheres can be evaluated for:
Nanofiltration studies
Membrane retention testing
Particle transport research
Pore-performance evaluation
Filter-material development
Separation-method research
Nanomaterial Research
Uniform polystyrene nanoparticles are suitable for:
Polymer nanocomposites
Nanoparticle assemblies
Coating development
Optical material research
Surface modification studies
Environmental particle research
Model nanoparticle systems
Recommended Sample Preparation
Mix the original suspension thoroughly.
Dilute with filtered water or a compatible dispersing medium.
Use clean, low-particle-background containers.
Prepare low concentrations by serial dilution.
Avoid contamination from dust and larger particles.
Confirm particle dispersion before measurement.
Prepare fresh diluted samples when possible.
Handling Recommendations
Mix thoroughly before sampling.
Avoid vigorous shaking that introduces bubbles.
Protect the suspension from contamination.
Do not allow the particles to dry.
Avoid freezing and repeated freeze–thaw cycles.
Use clean laboratory consumables.
Verify compatibility before adding salts or solvents.
Follow the product label for storage conditions.
Quality and Batch Documentation
Available documentation may include:
Product specification
Nominal particle size
Solids-content information
Batch identification
Particle-size test data when applicable
Storage recommendations
Safety Data Sheet
Certified diameter, measurement uncertainty and metrological traceability should only be claimed when specifically included in the supplied batch documents.
Customization and Bulk Supply
SHBC supports standard polystyrene microspheres for laboratory research, analytical method development and industrial projects.
Customization options include:
Different particle sizes
Solids-content adjustment
Suspension-medium adjustment
Surface functionalization
Custom packaging
Research samples
Pilot-scale supply
Bulk manufacturing
OEM and ODM cooperation
Why Choose SHBC?
Shanghai SanYu Biotechnology Co., Ltd. manufactures standard and functional microspheres for particle analysis, diagnostic research, optical materials and industrial applications.
SHBC provides:
Controlled particle-size production
Stable suspension formulation
Batch quality control
Flexible solids concentrations
Custom packaging
Technical application support
Research samples
Reliable bulk supply
Frequently Asked Questions
What is SPS40-10?
SPS40-10 is a 40nm standard polystyrene microsphere suspension with 5% solids content.
Is 40nm equal to 0.04µm?
Yes. A particle diameter of 40nm is equal to 0.04µm.
Can SPS40-10 be used for DLS?
Yes. It can be evaluated for DLS method development, repeatability testing and instrument performance verification.
Is SPS40-10 a certified reference material?
It should only be described as certified or traceable when certification, measurement uncertainty and traceability information are included in the supplied batch documents.
Can it be used for TEM or SEM?
Yes. The particles can be evaluated using electron microscopy after suitable sample preparation.
Can it be used for AFM?
Yes. SPS40-10 may be evaluated for nanoscale particle imaging and AFM method development.
Does SPS40-10 require dilution?
Most analytical applications require dilution. The optimal concentration depends on the instrument and measurement method.
Why choose a 5% solids suspension?
The 5% concentration provides flexibility for serial dilution, repeated measurement, formulation research and larger-scale projects.
Can SHBC provide other particle sizes?
Yes. SHBC supplies standard polystyrene microspheres in multiple nanoscale and microscale particle sizes.
Is bulk production available?
Yes. SHBC supports research samples, customized packaging, pilot quantities and bulk manufacturing.
Ordering Information
Product Name: 40nm Standard Polystyrene Microspheres
Catalog Number: SPS40-10
Nominal Particle Size: 40nm
Equivalent Particle Size: 0.04µm
Solids Content: 5%
Material: Polystyrene
Brand: SHBC
Manufacturer: Shanghai SanYu Biotechnology Co., Ltd.
Contact SHBC for samples, technical documents, customized concentrations and bulk production quotations.
For research and manufacturing use. Product suitability should be validated for the final measurement method and application.