
Products
SHBC provides colored microspheres, fluorescent microspheres, magnetic beads, silica microspheres, chromatography packing microspheres and biological reagents for diagnostic assay development, nucleic acid extraction, protein purification and separation applications.
-
Si500UM-10
-
SHBC
-
5%
-
500µm
-
10ml,20ml,50ml ,500ml,1000ml
500um Silica Microspheres for Immunoassay R&D
SHBC Si500UM-10 Silica Microspheres are large, spherical silica particles with a nominal diameter of 500 µm and a solid content of 5%.
They are designed for research projects requiring an easy-to-handle silica solid phase, including immunoassay carrier development, biomolecule immobilization, surface modification, packed-bed testing and filtration-assisted separation.
Si500UM-10 is available for laboratory evaluation, pilot production and bulk manufacturing.
Product Specifications
Item | Specification |
|---|---|
Product Name | 500um Silica Microspheres |
Catalog Number | Si500UM-10 |
Material | Silicon Dioxide, SiO₂ |
Nominal Particle Size | 500 µm |
Solid Content | 5% |
Surface | Native Silica Surface |
Surface Groups | Silanol Groups |
Product Form | Microsphere Dispersion |
Brand | SHBC |
Manufacturer | Shanghai SanYu Biotechnology Co., Ltd. |
Main Application | Immunoassay and Solid-Phase Carrier Research |
Supply Type | Samples, Pilot Orders and Bulk Production |
Intended Use | Research Use Only |
Key Features and Benefits
Large and Easy-to-Handle Particles
The 500 µm particle size allows easier visual handling, washing, recovery and process observation compared with nano- and small-micron particles.
Suitable for Solid-Phase Carrier Research
Si500UM-10 can be evaluated as a solid carrier for immobilizing antibodies, antigens, proteins, peptides and other biomolecules.
Easy Physical Separation
The large particle size supports sedimentation, filtration, mesh-based separation and packed-bed processing without requiring magnetic separation.
Silanol-Rich Surface
The native silica surface contains silanol groups that can support physical adsorption and silane-based surface modification.
Flexible Surface Functionalization
The silica surface may be further modified to introduce amino, carboxyl, epoxy, aldehyde, thiol or other functional groups.
Bulk Production Support
SHBC provides product samples, pilot-scale supply, customized specifications and stable batch manufacturing for research institutions and reagent developers.
Why Choose 500um Silica Microspheres?
The 500 µm size is suitable for assay and separation systems where convenient particle handling is more important than maintaining a stable nanoscale suspension.
Compared with smaller silica particles, large silica microspheres can provide:
Easier washing and recovery
Faster sedimentation
Convenient filtration
Better suitability for packed-bed formats
Easier observation during process development
Reduced dependence on high-speed centrifugation
Convenient transfer between reaction vessels
Potential reuse in selected research processes
Because 500 µm is much larger than particles commonly used in suspension immunoassays, customers should verify compatibility with their instrument, reaction vessel and detection format.
Applications in Immunoassay Development
Si500UM-10 can be evaluated for:
Solid-phase immunoassay carrier development
Antibody immobilization studies
Antigen coating research
Protein adsorption testing
Biomolecule coupling studies
Affinity capture carrier development
Filtration-assisted washing processes
Packed-bed immunoreaction systems
Column-based assay development
Diagnostic reagent raw material research
Surface chemistry screening
Bioconjugation process optimization
Large-particle biosensor research
Laboratory separation and purification studies
Final performance depends on the biomolecule, surface modification, buffer composition and assay design.
Biomolecule Adsorption and Surface Modification
The native silica surface may be used for preliminary physical adsorption studies.
Adsorption performance can be affected by:
Buffer pH
Ionic strength
Biomolecule concentration
Protein isoelectric point
Incubation time
Mixing method
Blocking reagent
Washing conditions
Storage buffer
For applications requiring stronger biomolecule attachment, the surface can be modified through silane chemistry before covalent coupling.
Potential functional surfaces include:
Amino-functional silica
Carboxyl-functional silica
Epoxy-functional silica
Aldehyde-functional silica
Thiol-functional silica
Biotin-functional silica
Streptavidin-coated silica
Protein A or Protein G coated silica
The appropriate surface chemistry should be selected according to the target biomolecule and assay format.
Suitable Solid-Phase Assay Formats
Si500UM-10 is especially suitable for research formats involving physical recovery or fixed positioning of the microspheres.
Potential formats include:
Packed-Bed Systems
Large silica microspheres can be evaluated as a stationary solid phase in columns, cartridges and flow-through research devices.
Filtration-Assisted Assays
The particles may be retained using an appropriate filter or mesh during washing and buffer exchange.
Batch Adsorption Systems
The microspheres can be mixed with target biomolecules and then recovered by sedimentation or filtration.
Visible Carrier Research
The large particle size allows easier observation and transfer during manual assay development.
Reusable Carrier Studies
Researchers can evaluate the regeneration and reuse of functionalized microspheres in suitable laboratory processes.
Recommended Handling
Mix the product gently before use to obtain a representative suspension.
Recommended precautions include:
Avoid allowing the silica microspheres to dry.
Use containers with sufficient opening width.
Select pipette tips or transfer tools suitable for 500 µm particles.
Avoid narrow tubing that may cause blockage.
Use gentle mixing to reduce particle damage.
Confirm that filters and meshes retain the particles.
Evaluate sedimentation before automated dispensing.
Optimize washing conditions for each assay.
Confirm buffer compatibility before scale-up.
Standard pipette tips designed for small particles may not be suitable for transferring 500 µm microspheres.
Application Development Considerations
Before using Si500UM-10 in an immunoassay, customers should confirm:
Whether the particles can pass through the dispensing system
Whether the reaction vessel provides sufficient mixing
Whether sedimentation affects reaction uniformity
Whether the detection instrument can accommodate large particles
Whether filtration or mesh separation is required
Whether physical adsorption provides sufficient binding stability
Whether surface functionalization is necessary
Whether the particle size is suitable for the final test format
Application-specific testing is recommended before pilot or commercial-scale production.
Customization and Bulk Manufacturing
Shanghai SanYu Biotechnology Co., Ltd. provides silica microsphere development and manufacturing services for biotechnology companies, diagnostic reagent developers and research institutions.
Available customization may include:
Different particle sizes
Different solid contents
Custom particle size ranges
Custom dispersion media
Amino surface modification
Carboxyl surface modification
Epoxy surface modification
Other functional surfaces
Custom packaging volumes
Pilot-scale manufacturing
Bulk production
OEM and ODM services
Customization feasibility depends on the required particle size, surface chemistry, concentration, packaging and order volume.
Why Choose SHBC?
Specialized microsphere manufacturer
Large 500 µm silica particle option
Standardized 5% solid content
Support for immunoassay carrier research
Native and functionalized surface options
Laboratory sample availability
Pilot-scale production support
Stable bulk manufacturing
Batch-to-batch consistency
Custom packaging options
OEM and ODM services
Technical support for product development
Quality Documentation
Product and batch documentation can be provided according to order requirements.
Available documents may include:
Certificate of Analysis
Safety Data Sheet
Product specification
Particle size information
Batch identification
Storage recommendations
Handling guidance
Please contact SHBC to confirm the available testing data for the required production batch.
Frequently Asked Questions
What is Si500UM-10?
Si500UM-10 is a 500 µm silica microsphere product with a solid content of 5%, manufactured by Shanghai SanYu Biotechnology Co., Ltd. under the SHBC brand.
What are 500um silica microspheres used for?
They can be evaluated as large solid-phase carriers for biomolecule immobilization, packed-bed testing, filtration-assisted assays, adsorption research and separation process development.
Are 500um silica microspheres suitable for all immunoassays?
No. The 500 µm size is larger than particles normally used in suspension immunoassays. Customers should confirm compatibility with their reaction vessel, dispensing equipment and detection method.
Can antibodies be adsorbed onto the silica surface?
Physical adsorption can be evaluated. Performance depends on antibody properties, buffer pH, ionic strength, incubation time and blocking conditions.
Can the surface be functionalized?
Yes. The native silica surface can be modified to introduce amino, carboxyl, epoxy and other functional groups.
How can the microspheres be separated?
Depending on the assay design, the particles may be separated by sedimentation, filtration, sieving or retention within a packed column.
Can the product be used in automated equipment?
Automation compatibility depends on the tubing diameter, dispensing nozzle, mixing system and reaction vessel. Equipment testing is required before use.
Does SHBC provide customized particle sizes?
Yes. Custom particle sizes, concentrations, surface groups, dispersion media and packaging formats can be discussed.
Are bulk quantities available?
Yes. SHBC supports sample evaluation, pilot orders and bulk production for research and reagent development projects.
Is Si500UM-10 a finished diagnostic reagent?
No. It is a raw material intended for research and diagnostic reagent development. Customers are responsible for application validation and regulatory evaluation.
Request Samples and Bulk Pricing
Contact SHBC for samples, technical specifications, customized silica microspheres and bulk quotations.
Please provide the following information when requesting a quotation:
Required quantity
Target application
Desired packaging volume
Required surface chemistry
Preferred dispersion medium
Expected annual demand
Product: 500um Silica Microspheres
Catalog Number: Si500UM-10
Particle Size: 500 µm
Solid Content: 5%
Brand: SHBC
Manufacturer: Shanghai SanYu Biotechnology Co., Ltd.
Intended Use: Research Use Only


