Products
SHBC provides colored microspheres, fluorescent microspheres, magnetic beads, silica microspheres, chromatography packing microspheres and biological reagents for diagnostic assay development, nucleic acid extraction, protein purification and separation applications.
The standard polystyrene surface supports the physical adsorption of antibodies, antigens and other proteins, making the particles suitable for immunoassay research and reagent manufacturing.
-
PS100-10
-
SHBC
-
5%
-
100nm
-
10ml,20ml,50ml ,500ml,1000ml
100nm Polystyrene Microspheres PS100-10
SHBC PS100-10 Polystyrene Microspheres are uniform 100nm latex particles supplied at 5% solids.
The standard polystyrene surface supports the physical adsorption of antibodies, antigens and other proteins, making the particles suitable for immunoassay research and reagent manufacturing.
Product Overview
PS100-10 provides a stable particle carrier for adsorption-based biomolecule immobilization.
Its 100nm particle size offers a high specific surface area for protein coating, while the 5% solids concentration supports laboratory evaluation, formulation development and bulk reagent production.
No chemical activation is normally required for initial physical adsorption studies.
Key Specifications
Parameter | Specification |
|---|---|
Product Name | Polystyrene Microspheres |
Catalog Number | PS100-10 |
Nominal Particle Size | 100nm |
Solids Content | 5% |
Material | Polystyrene |
Surface Type | Standard polystyrene |
Product Form | Aqueous suspension |
Immobilization Method | Physical adsorption |
Brand | SHBC |
Manufacturer | Shanghai SanYu Biotechnology Co., Ltd. |
Intended Use | Research and reagent development |
Advantages for Physical Adsorption
Uniform 100nm particle size
High specific surface area
Standard hydrophobic polystyrene surface
Suitable for passive protein adsorption
No EDC or NHS activation required
Stable aqueous dispersion
Easy dilution and formulation
Consistent batch production
Suitable for pilot and bulk manufacturing
Custom concentration and packaging available
Immunoassay Applications
PS100-10 Polystyrene Microspheres can be evaluated for:
Antibody adsorption
Antigen immobilization
Protein coating studies
Latex-enhanced immunoassays
Agglutination assay development
Immunoturbidimetric reagent research
Diagnostic reagent formulation
Blocking buffer screening
Non-specific adsorption studies
Biomolecule–particle interaction research
The final performance depends on the protein, coating concentration, buffer, pH, ionic strength and blocking system.
Physical Adsorption Principle
Proteins can adsorb onto the polystyrene surface through hydrophobic interactions, ionic interactions and other non-covalent forces.
The adsorption process is simple and does not require chemical coupling reagents. It is suitable for rapid antibody or antigen coating screening during early assay development.
Physical adsorption is less orientation-controlled than covalent coupling. Coating and blocking conditions should therefore be optimized for each biomolecule.
Recommended Coating Development
A typical development process includes:
Disperse the microspheres completely.
Dilute to the required working concentration.
Add the antibody, antigen or protein.
Incubate under controlled mixing conditions.
Separate or wash away unbound protein.
Add a suitable blocking reagent.
Resuspend in the storage buffer.
Evaluate sensitivity, stability and non-specific binding.
Protein concentration, pH, coating time and blocking formulation should be determined experimentally.
Why Choose 100nm Polystyrene Microspheres
The 100nm particle size provides a large surface area for biomolecule adsorption and is suitable for nanoscale immunoassay reagent development.
Compared with larger particles, 100nm microspheres provide more particles and more available coating surface at the same solids mass.
PS100-10 is suitable for customers requiring concentrated polystyrene latex raw material for formulation screening and scalable production.
Why Choose SHBC
Shanghai SanYu Biotechnology Co., Ltd. specializes in microsphere materials for immunoassay and life science research.
SHBC provides:
Controlled microsphere manufacturing
Stable particle dispersion
Batch-to-batch consistency
Laboratory and bulk quantities
Technical support for coating development
Flexible packaging options
OEM and private-label services
Customized surface chemistry
Bulk Supply and Customization
PS100-10 is available for research evaluation, pilot production and bulk manufacturing.
Customization options include:
Particle size
Solids concentration
Buffer formulation
Surfactant level
Preservative system
Surface functional groups
Bottle volume
Bulk packaging
OEM labeling
Carboxyl, amino and other functionalized polystyrene microspheres are also available for covalent biomolecule coupling.
Frequently Asked Questions
What is PS100-10?
PS100-10 is a 100nm polystyrene microsphere suspension supplied at 5% solids.
Can antibodies be adsorbed directly?
Yes. The standard polystyrene surface can be used for passive antibody and protein adsorption without chemical activation.
Is EDC/NHS activation required?
No. EDC/NHS activation is not normally required for physical adsorption onto standard polystyrene microspheres.
What proteins can be coated?
The particles can be evaluated for antibodies, antigens, enzymes and other proteins. Adsorption efficiency must be tested for each biomolecule.
Can PS100-10 be used for immunoturbidimetric assays?
It can be evaluated as a particle carrier for latex-enhanced immunoturbidimetric reagent development. The formulation and reaction conditions require application-specific optimization.
What affects physical adsorption?
Important factors include protein concentration, buffer pH, ionic strength, particle concentration, coating time, temperature and blocking reagent.
Is bulk production available?
Yes. SHBC supports sample testing, pilot-scale production and bulk supply for research institutions and immunoassay reagent manufacturers.
Can the concentration be customized?
Yes. Solids concentration, buffer, packaging and other specifications can be customized according to project requirements.
Research Use Only
PS100-10 Polystyrene Microspheres are intended for research use and reagent development only. They are not intended for direct clinical diagnosis or therapeutic use.