Products
SHBC provides colored microspheres, fluorescent microspheres, magnetic beads, silica microspheres, chromatography packing microspheres and biological reagents for diagnostic assay development, nucleic acid extraction, protein purification and separation applications.
-
CFR15UM-10
-
SHBC
-
1%
-
15µm
-
10ml,20ml,50ml ,500ml,1000ml
15um Carboxyl Red-Fluo Microspheres CFR15UM-10
SHBC CFR15UM-10 are 15 μm carboxyl-functionalized red fluorescent microspheres developed for flow cytometry, fluorescence imaging, particle-based assays and biomolecule immobilization.
The microspheres feature excitation at 535 nm, emission at 610 nm and 1% solid content. Surface carboxyl groups support covalent coupling with antibodies, antigens, proteins and peptides.
Product Specifications
Parameter | Specification |
|---|---|
Product Name | Carboxyl Red-Fluo Microspheres |
Catalog Number | CFR15UM-10 |
Nominal Particle Size | 15 μm |
Solid Content | 1% |
Surface Group | Carboxyl, COOH |
Excitation Wavelength | 535 nm |
Emission Wavelength | 610 nm |
Fluorescence Color | Red |
Supply Form | Suspension |
Brand | SHBC |
Manufacturer | Shanghai SanYu Biotechnology Co., Ltd. |
Batch-specific particle size, size distribution, carboxyl content and fluorescence data are available in the Certificate of Analysis.
Red Fluorescence at 535/610nm
CFR15UM-10 produces red fluorescence with excitation at approximately 535 nm and emission centered at approximately 610 nm.
The optical profile is suitable for compatible flow cytometers, fluorescence microscopes, imaging systems and fluorescence readers.
Key Advantages
Uniform 15um Particle Size
Controlled particle sizing supports repeatable fluorescence detection, biomolecule coupling and particle analysis.
Strong Signal per Particle
The 15 μm particle body provides a strong fluorescent signal for clear detection and imaging.
Reactive Carboxyl Surface
Surface COOH groups support covalent immobilization of antibodies, antigens, proteins, peptides and other amino-containing molecules.
Large Coupling Surface
The large particle diameter provides substantial surface area per particle for biomolecule immobilization.
Easy Separation and Washing
Micrometer-sized particles can be conveniently recovered by centrifugation during coupling and washing procedures.
Custom and Bulk Supply
SHBC supports samples, customized specifications, pilot production and industrial batch supply.
Main Applications
Flow Cytometry
CFR15UM-10 can be evaluated for fluorescence channel testing, particle counting, gating development and bead-based assays.
Fluorescence Microscopy
The red fluorescent signal supports particle localization, distribution and imaging studies.
Particle-Based Immunoassays
Antibodies or antigens can be immobilized on the carboxyl surface for suspension immunoassays and agglutination research.
Biomolecule Immobilization
Suitable for covalent coupling of proteins, enzymes, peptides and other amino-containing molecules.
Cell–Particle Interaction Studies
Can be evaluated in particle adhesion, cellular contact and selected uptake studies.
Fluid and Particle Tracing
Suitable for selected fluid-flow, filtration, microchannel and particle-transport research.
Instrument Evaluation
Can be used in fluorescence detection, particle counting and imaging method development.
Biomolecule Coupling
Surface carboxyl groups can be activated using EDC/NHS chemistry and coupled with primary amine groups on antibodies or proteins.
A typical workflow includes:
Wash and redisperse the microspheres.
Activate the carboxyl groups with EDC and NHS.
Add the antibody or target protein.
Block remaining reactive sites.
Wash and resuspend the conjugated particles.
Evaluate coupling and fluorescence performance.
Coupling pH, reagent concentration, protein loading and reaction time should be optimized for each biomolecule.
Coupling Benefits
CFR15UM-10 provides:
Reactive carboxyl groups
Large coupling surface
Stable covalent immobilization
Easy centrifugation and washing
Strong fluorescence detection
Flexible ligand modification
Compatibility with bead-based assays
Custom conjugation support
Flow Cytometry Considerations
Recommended parameters to optimize include:
Particle concentration
Excitation source
Emission filter
Sample flow rate
FSC and SSC settings
Detector voltage
Gating strategy
Doublet discrimination
Particle aggregation
Use an optical configuration compatible with 535 nm excitation and emission near 610 nm.
Because the particles are 15 μm, confirm that the instrument fluidics and flow cell can process the particle size.
Cell Study Considerations
For cell-related research, evaluate:
Particle-to-cell ratio
Cell type and size
Incubation time
Surface ligand density
Culture conditions
Washing efficiency
Particle internalization
Background fluorescence
The 15 μm particles may be too large for uptake by some cell types. Application suitability should be confirmed using the selected cell model.
Dispersion and Handling
Before use:
Mix by gentle inversion or controlled vortexing
Redisperse settled particles completely
Avoid excessive foam
Protect the suspension from strong light
Prevent the microspheres from drying
Avoid repeated freeze-thaw cycles
Confirm buffer compatibility
Use clean laboratory equipment
Controlled bath sonication may be used to break weak aggregates. Avoid aggressive probe sonication.
Centrifugation and Washing
The 15 μm particles can generally be recovered by low-speed centrifugation.
Optimize centrifugation according to:
Suspension volume
Buffer viscosity
Particle concentration
Tube type
Required recovery rate
Avoid excessive centrifugation that may produce a difficult-to-redisperse pellet.
Application Limitations
CFR15UM-10 is generally unsuitable for conventional nitrocellulose membrane migration because of its large particle size.
For standard fluorescent lateral flow assays, submicron fluorescent microspheres are normally more suitable.
The product is better suited to suspension assays, flow cytometry, fluorescence imaging, particle tracing and biomolecule coupling.
Custom Carboxyl Fluorescent Microspheres
SHBC can customize fluorescent microspheres according to research and production requirements.
Customization options may include:
Custom particle size
Custom fluorescence wavelength
Different fluorescence colors
Carboxyl group density
Solid content
Dispersion buffer
Surface modification
Biomolecule conjugation
Custom packaging
OEM and ODM production
Please provide the target application, required wavelength, biomolecule and order quantity when requesting customization.
Quality Control and Documents
Available product documents may include:
Certificate of Analysis
Technical Data Sheet
Safety Data Sheet
Particle size report
Particle size distribution data
Fluorescence spectrum
Carboxyl content data
Microscopy images
Batch inspection report
Why Choose SHBC?
Shanghai SanYu Biotechnology Co., Ltd. supplies fluorescent microspheres, colored latex particles, magnetic beads and functional microsphere materials.
SHBC provides:
Controlled microsphere manufacturing
Stable particle size distribution
Multiple fluorescence wavelengths
Functional surface modification
Batch-to-batch consistency
Sample evaluation support
Pilot and bulk production
OEM and ODM services
Frequently Asked Questions
What is CFR15UM-10?
CFR15UM-10 is a 15 μm carboxyl-functionalized red fluorescent microsphere suspension with 1% solid content.
What are the excitation and emission wavelengths?
The excitation wavelength is 535 nm and the emission wavelength is 610 nm.
What is CFR15UM-10 mainly used for?
It is suitable for flow cytometry, fluorescence microscopy, particle-based immunoassays, biomolecule coupling and particle-tracing studies.
Can antibodies be coupled to CFR15UM-10?
Yes. Antibodies and proteins containing primary amine groups can be covalently coupled to the carboxyl surface.
Which coupling chemistry is recommended?
EDC/NHS chemistry is commonly used to activate surface carboxyl groups for protein immobilization.
Is CFR15UM-10 suitable for flow cytometry?
Yes, provided the instrument fluidics can process 15 μm particles. Optical filters, scatter settings and gating conditions should be optimized.
Can CFR15UM-10 be used for cell uptake studies?
It can be evaluated with suitable cell models. The particle size may be too large for uptake by some cell types.
Is CFR15UM-10 suitable for lateral flow assays?
The 15 μm particles are generally too large for conventional nitrocellulose membrane migration. Smaller fluorescent microspheres are recommended for standard LFIA formats.
How should CFR15UM-10 be dispersed?
Use gentle inversion, controlled vortexing or compatible bath sonication while avoiding excessive foam and particle damage.
Can the particles be separated by centrifugation?
Yes. The particles can generally be recovered by centrifugation. Speed and time should be optimized for the working volume and buffer.
Can CFR15UM-10 be customized?
Yes. Particle size, fluorescence wavelength, carboxyl density, solid content, buffer, surface ligand and packaging can be customized.
Are samples and bulk quantities available?
Yes. SHBC supports laboratory samples, pilot orders and industrial batch production.
Request a Sample or Quotation
Contact SHBC for CFR15UM-10 samples, technical specifications, conjugation support and bulk pricing.
Please provide:
Target application
Target biomolecule
Detection instrument
Required quantity
Preferred packaging
Estimated annual demand
Product: 15um Carboxyl Red-Fluo Microspheres
Catalog Number: CFR15UM-10
Particle Size: 15 μm
Solid Content: 1%
Excitation/Emission: 535/610 nm
Surface Group: Carboxyl, COOH
Brand: SHBC
Manufacturer: Shanghai SanYu Biotechnology Co., Ltd.