
Products
SHBC provides colored microspheres, fluorescent microspheres, magnetic beads, silica microspheres, chromatography packing microspheres and biological reagents for diagnostic assay development, nucleic acid extraction, protein purification and separation applications.
-
MEP15UM-10
-
SHBC
-
5%
-
15µm
-
10ml,20ml,50ml,100ml,1000ml
15 μm Epoxy Magnetic Beads MEP15UM-10
SHBC MEP15UM-10 Epoxy Magnetic Beads are 15 μm functional magnetic microspheres supplied at 5% solids.
The reactive epoxy surface is designed for covalent immobilization of antibodies, antigens, proteins, peptides, enzymes and other compatible biomolecules.
MEP15UM-10 is suitable for immunoassay development, magnetic separation, biomolecule capture and scalable reagent production.
MEP15UM-10 Technical Specifications
Property | Specification |
|---|---|
Product Name | Epoxy Magnetic Beads |
Product Code | MEP15UM-10 |
Particle Size | 15 μm |
Surface Functionality | Epoxy |
Solid Content | 5% |
Form | Aqueous Suspension |
Main Function | Covalent Biomolecule Immobilization |
Brand | SHBC |
Manufacturer | Shanghai SanYu Biotechnology Co., Ltd. |
Epoxy Coupling Principle
Epoxy groups on the bead surface can react with compatible amino or sulfhydryl groups in antibodies, proteins, peptides and enzymes.
The resulting covalent attachment helps retain the immobilized ligand during magnetic separation and repeated washing. Epoxy magnetic beads are widely used to prepare customized antibody- or protein-functionalized particles.
Key Advantages of MEP15UM-10
Reactive epoxy-functional surface
15 μm particle size
Supplied at 5% solids
Direct covalent ligand immobilization
No EDC/NHS activation normally required
Suitable for antibodies, antigens and proteins
Convenient magnetic collection and washing
Stable ligand attachment
Flexible custom surface modification
Suitable for research and production scale-up
Why Choose 15 μm Epoxy Magnetic Beads?
The 15 μm particle format supports straightforward bead handling, magnetic collection and repeated washing.
MEP15UM-10 is suitable for projects requiring:
Easy magnetic solid-phase handling
Custom antibody-coated beads
Custom antigen-coated beads
Large-particle magnetic separation
Manual or automated washing
Scalable reagent preparation
Immunoassay Applications
Antibody-Coupled Magnetic Beads
Capture antibodies can be immobilized on MEP15UM-10 for:
Sandwich immunoassays
Chemiluminescent immunoassays
Fluorescent immunoassays
Enzyme immunoassays
Magnetic immunoassays
Biomarker detection
Pathogen-detection research
Antigen-Coupled Magnetic Beads
Antigens can be coupled for:
Antibody-detection assays
Serological research
Autoantibody assay development
Infectious-disease research
Assay calibration
Method validation
Automated Immunoassay Workflows
Magnetic beads simplify solid-phase collection, washing and buffer exchange.
MEP15UM-10 can be evaluated in:
Automated chemiluminescence analyzers
Magnetic washing instruments
Liquid-handling platforms
High-throughput assay systems
Custom diagnostic reagent platforms
Commercial epoxy magnetic-bead systems are commonly positioned for immunoassays, immunoprecipitation and automated magnetic processing.
Protein and Biomolecule Applications
MEP15UM-10 can also be evaluated for:
Immunoprecipitation
Protein enrichment
Protein-complex isolation
Enzyme immobilization
Affinity ligand preparation
Biomolecule capture
Biosensor development
Custom magnetic purification
Suitable Coupling Molecules
The epoxy-functional surface can be evaluated with:
Monoclonal antibodies
Polyclonal antibodies
Recombinant proteins
Antigens
Peptides
Enzymes
Lectins
Other compatible affinity ligands
Coupling efficiency depends on ligand purity, concentration, accessible functional groups and reaction conditions.
General Coupling Workflow
1. Resuspend the Beads
Mix the suspension thoroughly before sampling to obtain a uniform bead concentration.
2. Wash the Magnetic Beads
Collect the beads using a magnetic separator and replace the storage solution with a suitable coupling buffer.
3. Add the Ligand
Add the purified antibody, antigen, protein or enzyme to the washed beads.
4. Perform Covalent Coupling
Incubate under optimized buffer, temperature and mixing conditions.
5. Block Residual Epoxy Groups
Deactivate remaining reactive groups using a suitable blocking reagent.
6. Wash the Coupled Beads
Remove unbound biomolecules and reaction components through repeated magnetic washing.
7. Resuspend and Evaluate
Resuspend the functionalized beads in the selected storage or assay buffer and evaluate performance.
Factors Affecting Coupling Efficiency
Important optimization factors include:
Ligand purity
Ligand concentration
Bead-to-ligand ratio
Coupling-buffer composition
Buffer pH
Ionic strength
Reaction temperature
Incubation time
Mixing efficiency
Blocking conditions
Small-scale testing is recommended before production scale-up.
Immunoassay Development Tips
Use purified antibodies or antigens.
Avoid unnecessary carrier proteins.
Confirm buffer and preservative compatibility.
Keep beads uniformly suspended during coupling.
Optimize ligand loading for signal and background.
Block residual epoxy groups after coupling.
Evaluate nonspecific binding.
Confirm magnetic separation performance.
Test coupled-bead storage stability.
Verify batch-to-batch assay consistency.
Protein-containing additives may compete with the target ligand for reactive bead surfaces, so formulation components should be reviewed before coupling.
Scale-Up Quality Control
For bulk immunoassay reagent production, evaluate:
Particle-size consistency
Suspension uniformity
Solid-content consistency
Magnetic collection performance
Coupling efficiency
Ligand loading
Nonspecific binding
Signal-to-background ratio
Assay sensitivity
Storage stability
Batch reproducibility
MEP15UM-10 vs. Passive Adsorption Beads
Feature | Epoxy Magnetic Beads | Passive Adsorption Beads |
|---|---|---|
Immobilization | Covalent coupling | Physical adsorption |
Surface | Reactive epoxy groups | Non-reactive polymer surface |
Ligand Retention | Stable attachment | Depends on adsorption stability |
Washing Resistance | Suitable for repeated washing | Ligand loss may occur |
Process Control | Controlled coupling conditions | Controlled by adsorption conditions |
Main Use | Customized functional beads | Simple protein coating |
Why Choose SHBC MEP15UM-10?
15 μm epoxy-functional magnetic beads
5% solid-content suspension
Suitable for immunoassay development
Flexible antibody and antigen coupling
Research and manufacturing quantities
Sample evaluation support
Stable batch supply
Bulk production capability
Custom packaging options
Technical support for product selection
Storage and Handling
Store MEP15UM-10 according to the product label and technical documentation.
Recommended practices:
Keep the container tightly sealed.
Mix thoroughly before use.
Avoid freezing unless validated.
Prevent microbial contamination.
Use clean pipettes and containers.
Avoid prolonged magnetic collection during storage.
Review the SDS before use.
Frequently Asked Questions
What is MEP15UM-10?
MEP15UM-10 is a 15 μm epoxy-functional magnetic bead suspension supplied at 5% solids.
What biomolecules can be coupled?
The beads can be evaluated for antibodies, antigens, proteins, peptides, enzymes and other compatible ligands.
Is EDC/NHS activation required?
No. The surface already contains reactive epoxy groups, so EDC/NHS activation is not normally required.
Can antibodies be coupled directly?
Yes. Compatible functional groups on purified antibodies can react with the epoxy surface.
Can MEP15UM-10 be used for immunoassays?
Yes. It can be used to develop magnetic solid phases for antibody, antigen and biomarker-detection assays.
Why should residual epoxy groups be blocked?
Blocking deactivates unreacted surface groups and helps reduce unwanted downstream reactions.
Can the beads be used for immunoprecipitation?
Yes. After coupling a suitable antibody, the beads can be evaluated for immunoprecipitation and protein enrichment.
Are the beads suitable for automated systems?
The magnetic format can be evaluated in automated separation, washing and liquid-handling workflows.
Is coupling optimization necessary?
Yes. Ligand loading, buffer, pH, temperature, incubation time and blocking conditions should be optimized for each application.
Can SHBC supply bulk quantities?
Yes. SHBC supports sample evaluation, research supply and bulk production for immunoassay developers and reagent manufacturers.
Request MEP15UM-10 Samples
Contact Shanghai SanYu Biotechnology Co., Ltd. for samples, technical documentation and bulk quotations.
Please provide:
Target antibody or antigen
Immunoassay format
Coupling scale
Required bead quantity
Current coupling method
Target application
Estimated annual demand
MEP15UM-10 is supplied for research and development. Final diagnostic use requires validation by the customer.


