Products
SHBC provides colored microspheres, fluorescent microspheres, magnetic beads, silica microspheres, chromatography packing microspheres and biological reagents for diagnostic assay development, nucleic acid extraction, protein purification and separation applications.
-
CFR200-10
-
SHBC
-
1%
-
200nm
-
10ml,20ml,50ml ,500ml,1000ml
200nm Carboxyl Red-Fluo Microspheres CFR200-10 Overview
CFR200-10 200nm Carboxyl Red-Fluo Microspheres are high-performance fluorescent polymer microspheres designed for lateral flow immunoassay (LFIA), immunochromatography reagent development, antibody conjugation, and diagnostic assay manufacturing.
With a controlled particle size of 200nm, red fluorescent optical signal, carboxyl-functionalized surface, and 1% w/v solids concentration, CFR200-10 provides a reliable fluorescent labeling material for biotechnology companies, IVD manufacturers, and research laboratories.
The surface carboxyl groups enable covalent coupling with antibodies, proteins, antigens, peptides, and other biomolecules through EDC/NHS activation chemistry.
CFR200-10 is suitable for laboratory research, fluorescent conjugate development, pilot validation, and bulk production of immunochromatography reagents.
Product Specifications of CFR200-10 Red Fluorescent Microspheres
Parameter | Specification |
|---|---|
Product Name | 200nm Carboxyl Red-Fluo Microspheres |
Catalog Number | CFR200-10 |
Particle Size | 200nm |
Diameter | 0.2μm |
Fluorescence Color | Red |
Surface Functional Group | Carboxyl (-COOH) |
Solid Content | 1% w/v |
Material | Fluorescent Polymer Microspheres |
Dispersion Medium | Aqueous Suspension |
Application | LFIA, Immunoassay, Biomolecule Coupling |
Coupling Chemistry | EDC/NHS Activation |
Supply Type | Research, Pilot and Bulk Production |
Key Features of 200nm Carboxyl Red-Fluo Microspheres
200nm Particle Size for Optimized Immunochromatography Performance
CFR200-10 features a precisely controlled particle diameter of approximately 200nm.
Compared with smaller fluorescent nanoparticles, 200nm microspheres provide:
Higher fluorescent dye loading capacity
Stronger individual particle signal
Efficient antibody attachment
Good membrane retention
Stable conjugate formation
The 200nm size represents a widely evaluated range for lateral flow assay development because it provides a balance between optical signal strength and migration behavior.
It is suitable for companies developing fluorescent immunochromatography platforms requiring stable and reproducible signal output.
Strong Red Fluorescence for Quantitative Detection
CFR200-10 contains red fluorescent dye integrated within the polymer particle structure.
The fluorescent signal supports:
Quantitative lateral flow assays
Fluorescence reader detection
Digital immunochromatography systems
Multiplex assay platforms
Research diagnostic applications
Compared with conventional visual labels, fluorescence-based detection enables objective measurement and improved analytical evaluation.
Carboxyl Surface Chemistry for Antibody Coupling
The surface of CFR200-10 contains carboxyl functional groups (-COOH).
After activation with EDC/NHS chemistry, the microspheres can be covalently coupled with:
Monoclonal antibodies
Polyclonal antibodies
Antigens
Recombinant proteins
Peptides
Enzymes
Other amine-containing biomolecules
Stable covalent conjugation helps improve reagent consistency and supports commercial assay development.
Stable Dispersion and Reliable Batch Consistency
For industrial immunoassay production, raw material consistency is critical.
CFR200-10 provides:
Controlled particle size distribution
Good aqueous dispersion stability
Reliable conjugation performance
Consistent fluorescence intensity
Batch-to-batch reproducibility
These properties support the transition from laboratory development to commercial manufacturing.
Applications of CFR200-10 in Lateral Flow Immunoassays
Fluorescent Lateral Flow Assay Development
CFR200-10 can be used as a fluorescent reporter particle in lateral flow immunoassay development.
Typical applications include:
Infectious disease testing research
Biomarker detection
Food safety analysis
Veterinary diagnostics
Environmental monitoring
Pharmaceutical research
The red fluorescence signal can be detected using compatible fluorescence readers.
Antibody and Protein Conjugation
Carboxyl fluorescent microspheres provide a versatile platform for biological molecule immobilization.
Typical coupling targets:
Detection antibodies
Capture antibodies
Antigens
Proteins
Peptides
Nucleic acid probes
Researchers can optimize coupling density according to assay requirements.
Quantitative Immunochromatography Detection
Fluorescent lateral flow platforms allow:
Digital signal measurement
Quantitative analysis
Automated reader integration
Improved detection evaluation
CFR200-10 provides a suitable fluorescent labeling material for next-generation diagnostic platforms.
Diagnostic Reagent Manufacturing
CFR200-10 supports customers throughout the development process:
Material selection
Conjugate preparation
Strip optimization
Pilot production
Process transfer
Bulk manufacturing
How Do 200nm Fluorescent Microspheres Work in LFIA?
A typical fluorescent lateral flow assay includes:
Step 1: Fluorescent Conjugate Preparation
CFR200-10 microspheres are coupled with detection antibodies through carboxyl chemistry.
Step 2: Sample Application
The sample is added onto the test strip.
Step 3: Target Recognition
Target molecules bind with fluorescent antibody conjugates.
Step 4: Membrane Migration
The complexes migrate through the nitrocellulose membrane.
Step 5: Signal Capture
The target complex is captured at the test line.
Step 6: Fluorescence Detection
A fluorescence reader measures signal intensity.
Antibody Coupling Process of Carboxyl Red-Fluo Microspheres
Carboxyl Activation
CFR200-10 carboxyl groups are activated using EDC/NHS chemistry.
Important parameters:
pH condition
Activation time
Activator concentration
Particle concentration
Antibody Conjugation
Activated microspheres react with antibody amino groups.
Optimization factors:
Protein concentration
Particle/protein ratio
Temperature
Reaction time
Blocking and Purification
After coupling:
Unreacted groups are blocked
Free proteins are removed
Conjugate stability is evaluated
Performance Evaluation
Recommended testing:
Particle size
Fluorescence intensity
Coupling efficiency
Dispersion stability
Strip performance
Advantages of Fluorescent Microspheres Compared with Colloidal Gold
Feature | CFR200-10 Fluorescent Microspheres | Colloidal Gold |
|---|---|---|
Detection Method | Fluorescence | Visual Color |
Quantitative Detection | Supported | Limited |
Reader Compatibility | Excellent | Limited |
Multiplex Capability | Available | Limited |
Signal Analysis | Digital | Visual |
Surface Modification | Carboxyl Chemistry | Adsorption |
Quality Control and Bulk Production Capability
For IVD reagent manufacturers, consistent fluorescent microspheres are essential.
CFR200-10 quality control includes:
Particle Size Analysis
Ensures consistent migration and conjugation.
Fluorescence Performance Testing
Evaluates optical signal stability.
Surface Functional Group Testing
Confirms available carboxyl groups.
Solid Content Control
Maintains formulation accuracy.
Batch Consistency Evaluation
Supports reliable production scale-up.
Customization Options for CFR200-10
SHBC provides customized fluorescent microsphere solutions.
Particle Size Customization
Particle sizes can be optimized according to:
Membrane characteristics
Detection sensitivity
Assay design
Fluorescence Customization
Available options:
Different fluorescent colors
Customized emission properties
Reader compatibility
Surface Chemistry Customization
Available modifications:
Carboxyl
Amino
Streptavidin
Other functional groups
Solid Content Customization
Concentration can be adjusted according to:
Coupling process
Shipping requirements
Production workflow
OEM and Bulk Manufacturing Support
SHBC supports:
Research samples
Pilot batches
Bulk production
Customized packaging
Long-term supply
Frequently Asked Questions About CFR200-10
What are 200nm Carboxyl Red-Fluo Microspheres?
CFR200-10 are 200nm fluorescent polymer microspheres with carboxyl functional surfaces designed for lateral flow assays, immunoassay research, and antibody conjugation.
Can CFR200-10 be used for immunochromatography?
Yes. CFR200-10 is suitable for fluorescent immunochromatography reagent development and assay optimization.
How are antibodies coupled to CFR200-10?
Antibodies are commonly attached using EDC/NHS activation chemistry to form stable covalent bonds.
Why choose 200nm fluorescent microspheres?
200nm microspheres provide strong fluorescent signal, stable conjugation, and reliable assay performance.
Can CFR200-10 support bulk production?
Yes. SHBC supplies research quantities, pilot batches, and industrial-scale production.
Are customized specifications available?
Yes. Particle size, fluorescence properties, functional groups, concentration, and packaging can be customized.
Why Choose SHBC CFR200-10 Carboxyl Red-Fluo Microspheres?
SHBC specializes in fluorescent microsphere materials for immunodiagnostic research and reagent manufacturing.
CFR200-10 provides:
200nm controlled particle size
Red fluorescent labeling
Carboxyl functional surface
Reliable antibody conjugation
LFIA development support
Bulk production capability
OEM customization services
Contact SHBC for samples, technical specifications, and bulk quotation for 200nm Carboxyl Red-Fluo Microspheres CFR200-10.