Products
SHBC provides colored microspheres, fluorescent microspheres, magnetic beads, silica microspheres, chromatography packing microspheres and biological reagents for diagnostic assay development, nucleic acid extraction, protein purification and separation applications.
-
MagNHS200-10
-
SHBC
-
5%
-
200nm
-
10ml,20ml,50ml ,500ml,1000ml
200nm NHS Magnetic Beads for Immunoassay Research
SHBC MNHS200-10 NHS Magnetic Beads are 200nm magnetic nanoparticles with an NHS-activated surface.
They are designed for direct covalent coupling of antibodies, antigens, proteins, peptides and other amine-containing biomolecules.
The product is supplied at 5% solids for immunoassay research, magnetic separation, affinity capture and bulk reagent production.
Product: 200nm NHS Magnetic Beads
Catalog Number: MNHS200-10
Brand: SHBC
Manufacturer: Shanghai SanYu Biotechnology Co., Ltd.
Particle Size: 200nm
Surface: NHS activated
Solids Content: 5%
Main Application: Immunoassay research
Supply: Samples, pilot batches and bulk production
Use: Research use only
Product Overview
MNHS200-10 provides a ready-to-couple magnetic surface.
NHS groups react with primary amino groups on antibodies and proteins. This forms stable covalent amide bonds.
The user does not need to activate carboxyl groups with EDC and NHS before coupling.
This reduces preparation steps and simplifies magnetic reagent development.
Technical Specifications
Parameter | Specification |
|---|---|
Product name | NHS Magnetic Beads |
Catalog number | MNHS200-10 |
Brand | SHBC |
Nominal diameter | 200nm |
Surface group | NHS ester |
Solids content | 5% |
Separation | Magnetic |
Coupling target | Primary amine-containing molecules |
Main use | Immunoassay research |
Supply format | Sample and bulk supply |
The following data should be confirmed by the final TDS or lot-specific COA:
Actual particle-size range
Particle-size CV
Magnetic material
Magnetic content
Magnetic response time
NHS-group density
Antibody coupling capacity
Protein coupling capacity
Suspension buffer
Preservative
Storage temperature
Package size
Shelf life
Key Advantages
Ready-to-Couple Surface
The NHS surface is already activated.
No additional EDC/NHS activation step is normally required.
Simple Antibody Coupling
Mix the beads with an antibody in a compatible amine-free buffer.
The antibody can react directly with the NHS surface.
Stable Covalent Bond
NHS groups react with primary amines to form stable amide linkages.
The coupled ligand is resistant to loss during repeated washing.
200nm Particle Size
The nanoscale particles provide a high particle number and large collective surface area.
This can support rapid suspension-phase interaction and small reaction volumes.
Magnetic Separation
The beads can be collected with an external magnetic field.
This simplifies washing, buffer exchange and removal of unbound reagents.
Suitable for Automation
The magnetic format can be evaluated in manual, semi-automated and automated immunoassay workflows.
Actual magnetic collection and redispersion must be validated on the intended instrument.
5% Solids Content
The concentrated suspension supports laboratory dilution, pilot coupling and production-scale reagent preparation.
Bulk Supply
SHBC supports research samples, pilot lots, repeated orders, OEM projects and enterprise bulk purchasing.
How NHS Coupling Works
NHS esters react with primary amino groups on biomolecules.
Primary amino groups are commonly present on:
Lysine residues
Protein N-termini
Peptide N-termini
Amino-modified oligonucleotides
Amino-modified synthetic ligands
The simplified reaction is:
NHS Magnetic Bead + Amine-Containing Ligand → Covalently Coupled Bead–Ligand
The coupling reaction should use an amine-free buffer.
Avoid Tris, glycine and other primary amine-containing components during coupling because they may consume NHS groups and reduce ligand loading.
NHS groups are also sensitive to hydrolysis. Prepare and use the beads according to the validated coupling procedure.
Immunoassay Applications
Magnetic Sandwich Immunoassays
Couple a capture antibody to MNHS200-10.
The antibody-coated beads can capture a target antigen from the sample.
A labeled detection antibody is then added to generate the assay signal.
Chemiluminescent Immunoassay Research
MNHS200-10 can be evaluated as a magnetic solid phase in CLIA and CLEIA reagent development.
Potential targets include:
Hormones
Cytokines
Tumor biomarkers
Cardiac biomarkers
Inflammatory markers
Infectious-disease antigens
Autoantibodies
Veterinary biomarkers
Competitive Immunoassays
NHS magnetic beads may be used for small molecules, haptens, drugs, hormones, toxins and other targets suitable for competitive assay formats.
Antigen-Coated Magnetic Beads
Recombinant antigens and proteins can be immobilized for:
Antibody detection
Serological assay research
Autoantibody research
Vaccine-response studies
Antibody screening
Affinity Capture
Antibody- or protein-coated beads can be used for:
Target enrichment
Immunoprecipitation research
Protein purification research
Antigen capture
Protein interaction studies
Automated Magnetic Washing
The magnetic solid phase supports:
Sample incubation
Magnetic capture
Supernatant removal
Repeated washing
Reporter incubation
Final signal detection
Suitable Coupling Molecules
MNHS200-10 may be evaluated with:
Monoclonal antibodies
Polyclonal antibodies
Recombinant antibodies
Antigens
Recombinant proteins
Peptides
Enzymes
Lectins
Receptors
Amino-modified oligonucleotides
Amino-modified aptamers
Amine-containing synthetic ligands
The ligand must contain an accessible primary amino group.
Recommended Coupling Workflow
1. Resuspend the Beads
Mix MNHS200-10 until the suspension is homogeneous.
Avoid excessive foaming.
2. Magnetically Collect the Beads
Place the tube in a compatible magnetic separator.
Remove the storage solution after the beads have collected.
3. Wash with Coupling Buffer
Use a validated amine-free buffer.
Do not use Tris or glycine during the coupling reaction.
4. Prepare the Ligand
Transfer the antibody or protein into the coupling buffer.
Remove incompatible stabilizers or free amines when necessary.
5. Add the Ligand
Mix the ligand with the NHS magnetic beads immediately after bead preparation.
6. Incubate
Maintain gentle mixing during coupling.
Optimize:
Ligand concentration
Bead concentration
Buffer pH
Reaction time
Temperature
Mixing speed
7. Wash the Coupled Beads
Magnetically collect the beads.
Remove unbound ligand with a suitable wash buffer.
8. Quench Remaining NHS Groups
Use an application-compatible quenching reagent.
This helps reduce unwanted surface reactions and assay background.
9. Block and Formulate
Add a suitable blocker and storage formulation.
Evaluate dispersion, magnetic recovery, ligand activity and stability.
Magnetic Immunoassay Workflow
Couple the capture antibody to MNHS200-10.
Quench and block the coupled beads.
Add the sample.
Incubate to capture the target.
Magnetically separate and wash.
Add the labeled detection antibody.
Incubate again.
Perform final magnetic washing.
Add the detection substrate.
Measure the signal.
Possible detection formats include:
Chemiluminescence
Fluorescence
Enzyme colorimetry
Electrochemiluminescence
Other compatible reporter systems
NHS Magnetic Beads vs Carboxyl Magnetic Beads
Feature | NHS Magnetic Beads | Carboxyl Magnetic Beads |
|---|---|---|
Surface state | Pre-activated | Requires activation |
Main target group | Primary amines | Primary amines after EDC/NHS activation |
Activation step | Normally unnecessary | Required |
Workflow | Shorter | More process steps |
Timing sensitivity | NHS hydrolysis must be controlled | Activation and hydrolysis must be controlled |
Best use | Rapid direct protein coupling | Flexible established coupling processes |
Choose NHS magnetic beads when a shorter direct-coupling workflow is preferred.
Choose carboxyl magnetic beads when the user already has a validated EDC/NHS process.
Quality Control
Recommended quality-control items include:
Particle diameter
Particle-size CV
Suspension appearance
Solids content
NHS activity
Magnetic response
Magnetic recovery
Redispersion
Antibody coupling capacity
Functional target binding
Non-specific binding
Aggregate level
Batch consistency
Coupling Efficiency
Coupling efficiency can be estimated by measuring:
Initial protein concentration
Protein remaining after coupling
Protein in wash solutions
Protein uptake does not equal functional antibody activity.
Always confirm performance with a target-binding immunoassay.
Functional Testing
A model immunoassay may compare:
Positive signal
Negative background
Signal-to-background ratio
Precision
Recovery
Magnetic washing efficiency
Lot-to-lot consistency
Bulk Manufacturing and Customization
Shanghai SanYu Biotechnology Co., Ltd. supports:
Research samples
Pilot batches
Bulk production
OEM supply
Private-label packaging
Custom catalog numbers
Custom package sizes
Custom solids concentration
Custom NHS-group density
Custom magnetic response
Customer-specific quality standards
For project evaluation, provide:
Required quantity
Annual demand
Intended immunoassay
Ligand type
Required coupling capacity
Magnetic separator or analyzer
Preferred package size
Buffer restrictions
Preservative restrictions
Quality-control requirements
Handling and Storage
Follow the final SHBC product label, TDS and lot-specific COA.
General recommendations:
Store under the specified refrigerated conditions.
Do not freeze unless validated.
Keep the container tightly closed.
Mix before sampling.
Do not allow the beads to dry.
Use clean, low-binding tubes.
Protect NHS groups from moisture and hydrolysis.
Avoid amine-containing buffers before coupling.
Use prepared beads promptly according to the validated procedure.
Frequently Asked Questions
What is MNHS200-10?
MNHS200-10 is a 200nm NHS-activated magnetic bead suspension supplied at 5% solids.
What is the main application?
It is designed for antibody and protein coupling in immunoassay research.
Is EDC/NHS activation required?
No additional EDC/NHS activation is normally required because the surface is already NHS activated.
Which groups react with NHS?
NHS esters mainly react with primary amino groups.
Can antibodies be coupled?
Yes. Antibodies containing accessible primary amino groups can be covalently immobilized.
Can antigens and proteins be coupled?
Yes. Recombinant antigens, proteins, peptides and enzymes may be evaluated.
Which buffers should be avoided?
Avoid Tris, glycine and other primary amine-containing buffers during coupling.
Is quenching required?
Quenching remaining NHS groups is generally recommended after ligand coupling.
Can the beads be used in CLIA research?
Yes. They can be evaluated as a magnetic solid phase in chemiluminescent immunoassay development.
Can the product be used on automated analyzers?
Yes, subject to validation of magnetic response, dispensing, washing and redispersion on the intended instrument.
What is the antibody coupling capacity?
Use the final product specification or lot-specific COA. Do not estimate it from solids content alone.
How are the beads separated?
Use an external magnetic separator compatible with the vessel and sample volume.
Can the beads be frozen?
Freezing is generally not recommended unless validated.
Is bulk production available?
Yes. SHBC supports samples, pilot batches, OEM projects and bulk manufacturing.
Request a Sample or Quotation
SHBC MNHS200-10 provides:
200nm nominal particle size
NHS-activated surface
5% solids content
Direct amine-based coupling
Stable covalent ligand attachment
Magnetic separation
Immunoassay compatibility
Sample and bulk supply
OEM and customization support
Product Name: 200nm NHS Magnetic Beads
Catalog Number: MNHS200-10
Brand: SHBC
Manufacturer: Shanghai SanYu Biotechnology Co., Ltd.
Particle Size: 200nm
Surface: NHS activated
Solids Content: 5%
Application: Immunoassay research
Supply: Samples, pilot batches and bulk production
Intended Use: Research Use Only. Not for diagnostic or therapeutic use.