200µm Polystyrene Microspheres PS200UM-10
SHBC PS200UM-10 Polystyrene Microspheres are uniform 200µm polymer beads supplied as a 5% aqueous suspension.
The plain polystyrene surface supports physical adsorption of antibodies, antigens and other proteins. The large particle size allows convenient microscopic observation, filtration, sedimentation and bead recovery.
Product Overview
PS200UM-10 is designed for large-particle immunoassay research, protein adsorption studies and bead-based method development.
Unlike nanometer latex particles, 200µm microspheres are easy to observe and handle individually. They are suitable for applications requiring a visible, recoverable and mechanically stable polystyrene carrier.
Key Specifications
Parameter | Specification |
|---|
Product Name | Polystyrene Microspheres |
Catalog Number | PS200UM-10 |
Nominal Particle Size | 200µm |
Solids Content | 5% |
Particle Material | Polystyrene |
Surface Type | Plain polystyrene |
Immobilization Method | Physical adsorption |
Product Form | Aqueous suspension |
Brand | SHBC |
Manufacturer | Shanghai SanYu Biotechnology Co., Ltd. |
Intended Use | Research and reagent development |
Key Product Advantages
Uniform 200µm particle size
Easy microscopic observation
Plain hydrophobic polystyrene surface
Suitable for passive protein adsorption
Easy separation by sedimentation or filtration
Convenient washing and bead recovery
Stable spherical particle carrier
Suitable for large-particle assay development
Consistent batch manufacturing
Bulk and customized supply available
Physical Adsorption of Proteins
Antibodies, antigens and other proteins can adsorb onto the plain polystyrene surface through hydrophobic, ionic and other non-covalent interactions.
Physical adsorption provides a simple coating method without EDC or NHS activation.
Important development parameters include:
Protein concentration
Buffer pH
Ionic strength
Coating time
Mixing speed
Blocking reagent
Washing conditions
Storage formulation
Coating efficiency and biological activity should be evaluated for each protein.
Immunoassay and Research Applications
PS200UM-10 can be evaluated for:
Antibody adsorption studies
Antigen immobilization
Large-particle immunoassay carriers
Bead-based binding assays
Protein coating optimization
Blocking reagent screening
Non-specific adsorption studies
Microscopy method development
Particle counting and imaging
Filtration and separation research
Model particle experiments
Biotechnology process validation
Why Choose 200µm Microspheres
The large 200µm particle size provides clear visibility under conventional microscopy and simplifies physical collection.
Compared with nanoscale particles, PS200UM-10 offers:
Easier individual particle observation
Faster gravitational sedimentation
Simpler filtration and sieving
Easier washing and recovery
Lower risk of loss during routine handling
A defined large-particle surface for coating studies
These particles are suitable when easy handling and visual analysis are more important than maximum surface area.
Handling and Application Considerations
Because 200µm microspheres settle faster than nanometer latex particles, the suspension should be gently mixed before sampling.
Continuous or intermittent mixing may be required during protein coating to maintain uniform particle contact.
Avoid aggressive mixing that may generate foam or damage adsorbed proteins. A wide-bore pipette tip is recommended when transferring the suspension.
PS200UM-10 is not intended as a direct replacement for nanoscale latex particles used in conventional immunoturbidimetric reagents.
Why Choose SHBC
Shanghai SanYu Biotechnology Co., Ltd. manufactures microsphere materials for immunoassay, biotechnology and life science research.
SHBC provides:
Controlled particle manufacturing
Reliable particle size consistency
Stable batch-to-batch supply
Laboratory and production quantities
Flexible technical specifications
OEM and private-label services
Application-oriented technical support
Bulk Supply and Customization
PS200UM-10 is available for laboratory evaluation, pilot production and bulk manufacturing.
Customization options include:
Particle diameter
Particle size range
Solids concentration
Surface chemistry
Buffer formulation
Surfactant concentration
Preservative system
Packaging volume
OEM labeling
Carboxyl, amino and other functionalized surfaces can also be developed for covalent biomolecule coupling.
Frequently Asked Questions
What is PS200UM-10?
PS200UM-10 is a 200µm plain polystyrene microsphere suspension supplied at 5% solids.
Can antibodies be adsorbed directly?
Yes. Antibodies and other proteins can be physically adsorbed onto the plain polystyrene surface.
Is chemical activation required?
No chemical activation is normally required for physical adsorption. Coating and blocking conditions must still be optimized.
What is the advantage of the 200µm size?
The large particles are easy to observe, filter, wash, recover and analyze individually.
Can PS200UM-10 be used for immunoturbidimetric assays?
It is not designed as a direct replacement for nanoscale latex particles commonly used in immunoturbidimetric reagents. It is better suited for large-particle binding assays and protein coating research.
Will the particles settle during storage or use?
Yes. Large 200µm particles may settle relatively quickly. Gently mix the suspension before sampling and during coating when necessary.
Can the particle surface be customized?
Yes. Plain, carboxyl, amino and other customized surface chemistries can be supplied according to project requirements.
Is bulk production available?
Yes. SHBC supports sample evaluation, pilot-scale production and bulk supply for research institutions and reagent manufacturers.
Research Use Only
PS200UM-10 Polystyrene Microspheres are intended for research use and reagent development only. They are not intended for direct clinical diagnosis or therapeutic use.