Products
SHBC provides colored microspheres, fluorescent microspheres, magnetic beads, silica microspheres, chromatography packing microspheres and biological reagents for diagnostic assay development, nucleic acid extraction, protein purification and separation applications.
-
MEP20UM-10
-
SHBC
-
5%
-
20µm
-
10ml,20ml,50ml ,500ml,1000ml
20 μm Epoxy Magnetic Beads MEP20UM-10
SHBC MEP20UM-10 Epoxy Magnetic Beads are 20 μm functional magnetic microspheres supplied at 5% solids.
The reactive epoxy surface supports covalent immobilization of antibodies, antigens, proteins, peptides, enzymes and other compatible biomolecules.
MEP20UM-10 is designed for immunoassay development, magnetic separation, biomolecule capture and scalable reagent production.
MEP20UM-10 Technical Specifications
Property | Specification |
|---|---|
Product Name | Epoxy Magnetic Beads |
Product Code | MEP20UM-10 |
Particle Size | 20 μm |
Surface Functionality | Epoxy |
Solid Content | 5% |
Main Function | Covalent Biomolecule Immobilization |
Brand | SHBC |
Manufacturer | Shanghai SanYu Biotechnology Co., Ltd. |
Epoxy Coupling Mechanism
Epoxy groups on the bead surface can react with compatible amino or sulfhydryl groups in proteins and other biomolecules.
This reaction creates stable covalent attachment between the ligand and magnetic bead surface. Additional EDC/NHS activation is normally unnecessary because the beads already contain reactive epoxy groups.
After coupling, the beads can be magnetically collected, washed and resuspended for downstream assays.
Key Advantages of MEP20UM-10
Reactive epoxy-functional surface
20 μm particle size
Supplied at 5% solids
Direct covalent ligand immobilization
Suitable for antibodies, antigens and proteins
Strong ligand retention during washing
Convenient magnetic collection
Easy buffer exchange
Flexible custom surface modification
Suitable for research and bulk production
Why Choose 20 μm Epoxy Magnetic Beads?
The 20 μm particle format is suitable for workflows that prioritize straightforward particle handling, magnetic collection and repeated washing.
MEP20UM-10 can be evaluated for:
Magnetic solid-phase immunoassays
Large-particle assay systems
Custom antibody-coated beads
Custom antigen-coated beads
Manual magnetic separation
Automated magnetic washing
Scalable reagent preparation
Coupling capacity and assay performance should be validated for the selected ligand and application.
Immunoassay Applications
Antibody-Coupled Magnetic Beads
Capture antibodies can be covalently immobilized on MEP20UM-10 for:
Sandwich immunoassays
Chemiluminescent immunoassays
Fluorescent immunoassays
Enzyme immunoassays
Magnetic immunoassays
Biomarker detection
Pathogen-detection research
The magnetic solid phase simplifies target capture, washing and separation.
Antigen-Coupled Magnetic Beads
Antigens can be immobilized for:
Antibody-detection assays
Serological research
Autoantibody assay development
Infectious-disease research
Assay calibration
Method validation
Automated Immunoassay Workflows
MEP20UM-10 can be evaluated in:
Automated chemiluminescence analyzers
Magnetic washing instruments
Liquid-handling platforms
High-throughput assay systems
Custom diagnostic reagent platforms
Protein and Biomolecule Applications
MEP20UM-10 may also be evaluated for:
Immunoprecipitation
Protein enrichment
Protein-complex isolation
Enzyme immobilization
Affinity ligand preparation
Biomolecule capture
Biosensor development
Custom magnetic purification
Suitable Coupling Molecules
The epoxy-functional surface can be evaluated with:
Monoclonal antibodies
Polyclonal antibodies
Recombinant proteins
Antigens
Peptides
Enzymes
Lectins
Haptens
Other compatible affinity ligands
Final coupling efficiency depends on ligand purity, concentration, accessible functional groups and reaction conditions.
General Coupling Workflow
1. Resuspend the Beads
Mix the suspension thoroughly before sampling to obtain a uniform bead concentration.
2. Wash the Beads
Collect the beads with a magnetic separator and replace the storage solution with a suitable coupling buffer.
3. Add the Ligand
Add the purified antibody, antigen, protein or enzyme to the washed beads.
4. Perform Covalent Coupling
Incubate under optimized buffer, temperature and mixing conditions.
5. Block Residual Reactive Groups
Use a suitable blocking reagent to deactivate remaining epoxy groups.
6. Wash the Coupled Beads
Remove unbound biomolecules and reaction components through magnetic washing.
7. Resuspend and Evaluate
Resuspend the functionalized beads in the selected storage or assay buffer and evaluate performance.
Factors Affecting Coupling Efficiency
Important optimization factors include:
Ligand purity
Ligand concentration
Bead-to-ligand ratio
Coupling-buffer composition
Buffer pH
Ionic strength
Reaction temperature
Incubation time
Mixing efficiency
Blocking conditions
Small-scale optimization is recommended before bulk production.
Immunoassay Development Tips
Use purified antibodies or antigens.
Avoid unnecessary carrier proteins.
Confirm preservative and buffer compatibility.
Keep beads uniformly suspended during coupling.
Optimize ligand loading for signal and background.
Block residual epoxy groups after coupling.
Evaluate nonspecific binding.
Confirm magnetic separation efficiency.
Test coupled-bead storage stability.
Verify batch-to-batch assay performance.
Quality Control for Bulk Production
For research-to-production scale-up, evaluate:
Particle-size consistency
Suspension uniformity
Solid-content consistency
Magnetic collection performance
Coupling efficiency
Ligand loading
Nonspecific binding
Signal-to-background ratio
Assay sensitivity
Storage stability
Batch reproducibility
Epoxy vs. Carboxyl Magnetic Beads
Feature | Epoxy Magnetic Beads | Carboxyl Magnetic Beads |
|---|---|---|
Reactive Surface | Epoxy groups | Carboxyl groups |
Typical Activation | No additional activation normally required | EDC/NHS activation commonly used |
Coupling Targets | Amino- or thiol-containing ligands | Mainly amino-containing ligands |
Workflow | Direct covalent coupling | Activation followed by coupling |
Main Advantage | Simplified direct immobilization | Flexible coupling-condition control |
Typical Use | Custom antibody and protein beads | Immunoassay and biomolecule coupling |
The preferred chemistry depends on the ligand, required orientation, coupling conditions and final assay performance.
Why Choose SHBC MEP20UM-10?
20 μm epoxy-functional magnetic beads
5% solid-content suspension
Suitable for immunoassay development
Flexible antibody and antigen coupling
Research and manufacturing quantities
Sample evaluation support
Stable batch supply
Bulk production capability
Custom packaging options
Technical communication for product selection
Storage and Handling
Store MEP20UM-10 according to the product label and technical documentation.
Recommended handling practices:
Keep the container tightly sealed.
Mix thoroughly before use.
Avoid freezing unless validated.
Prevent microbial contamination.
Use clean pipettes and containers.
Avoid prolonged magnetic collection during storage.
Review the SDS before use.
Frequently Asked Questions
What is MEP20UM-10?
MEP20UM-10 is a 20 μm epoxy-functional magnetic bead suspension supplied at 5% solids.
What biomolecules can be coupled?
The beads can be evaluated for coupling antibodies, antigens, proteins, peptides, enzymes and other compatible ligands.
Is EDC/NHS activation required?
No. The surface already contains reactive epoxy groups, so EDC/NHS activation is not normally required.
Can antibodies be coupled directly?
Yes. Compatible functional groups on purified antibodies can react with the epoxy-functional surface.
Can MEP20UM-10 be used for immunoassays?
Yes. It can be evaluated as a magnetic solid phase for antibody, antigen and biomarker-detection assays.
Why should residual epoxy groups be blocked?
Blocking deactivates unreacted surface groups and helps reduce unwanted reactions during downstream use.
Can the beads be used for protein purification?
Yes. After coupling a suitable affinity ligand, the beads can be evaluated for protein capture, enrichment and purification.
Are the beads suitable for automated systems?
The magnetic format can be evaluated in automated separation, washing and liquid-handling workflows.
Is coupling optimization necessary?
Yes. Ligand loading, buffer, pH, temperature, reaction time and blocking conditions should be optimized for each project.
Can SHBC supply bulk quantities?
Yes. SHBC supports sample evaluation, research supply and bulk production for immunoassay developers and reagent manufacturers.
Request MEP20UM-10 Samples
Contact Shanghai SanYu Biotechnology Co., Ltd. for MEP20UM-10 samples, technical documentation and bulk quotations.
Please provide:
Target antibody or antigen
Immunoassay format
Coupling scale
Required bead quantity
Current coupling method
Target application
Estimated annual demand
MEP20UM-10 is supplied for research and development. Final diagnostic applications must be validated by the customer.