Products
SHBC provides colored microspheres, fluorescent microspheres, magnetic beads, silica microspheres, chromatography packing microspheres and biological reagents for diagnostic assay development, nucleic acid extraction, protein purification and separation applications.
-
MEP30UM-10
-
SHBC
-
5%
-
30µm
-
10ml,20ml,50ml ,500ml,1000ml
30 μm Epoxy Magnetic Beads MEP30UM-10
SHBC MEP30UM-10 Epoxy Magnetic Beads are 30 μm functional magnetic microspheres supplied at 5% solids.
The reactive epoxy surface supports covalent immobilization of antibodies, antigens, proteins, peptides, enzymes and other compatible biomolecules.
MEP30UM-10 is designed for immunoassay development, magnetic separation, biomolecule capture and scalable reagent production.
MEP30UM-10 Technical Specifications
Property | Specification |
|---|---|
Product Name | Epoxy Magnetic Beads |
Product Code | MEP30UM-10 |
Particle Size | 30 μm |
Surface Functionality | Epoxy |
Solid Content | 5% |
Form | Aqueous Suspension |
Main Function | Covalent Biomolecule Immobilization |
Brand | SHBC |
Manufacturer | Shanghai SanYu Biotechnology Co., Ltd. |
Epoxy Coupling Principle
Epoxy groups on the bead surface can react with compatible amino or sulfhydryl groups in antibodies, proteins, peptides and enzymes.
This reaction creates stable covalent attachment between the biomolecule and magnetic bead surface. Additional EDC/NHS activation is normally unnecessary because reactive epoxy groups are already present.
After coupling, the beads can be magnetically collected, washed and resuspended for downstream applications.
Key Advantages of MEP30UM-10
Reactive epoxy-functional surface
30 μm particle size
Supplied at 5% solids
Direct covalent ligand immobilization
Suitable for antibodies, antigens and proteins
Strong ligand retention during washing
Convenient magnetic separation
Easy buffer exchange
Flexible custom surface modification
Suitable for research and bulk production
Why Choose 30 μm Epoxy Magnetic Beads?
The larger 30 μm particle format supports convenient handling, magnetic collection and repeated washing.
MEP30UM-10 is suitable for workflows requiring:
Larger magnetic solid phases
Straightforward bead recovery
Custom antibody-coated beads
Custom antigen-coated beads
Manual magnetic separation
Automated magnetic washing
Scalable reagent preparation
Because larger beads may settle faster than smaller particles, uniform mixing is recommended during coupling and assay use.
Immunoassay Applications
Antibody-Coupled Magnetic Beads
Capture antibodies can be covalently immobilized on MEP30UM-10 for:
Sandwich immunoassays
Chemiluminescent immunoassays
Fluorescent immunoassays
Enzyme immunoassays
Magnetic immunoassays
Biomarker detection
Pathogen-detection research
The magnetic solid phase simplifies target capture, washing and separation.
Antigen-Coupled Magnetic Beads
Antigens can be immobilized for:
Antibody-detection assays
Serological research
Autoantibody assay development
Infectious-disease research
Assay calibration
Method validation
Automated Immunoassay Workflows
MEP30UM-10 can be evaluated in:
Automated chemiluminescence analyzers
Magnetic washing instruments
Liquid-handling platforms
High-throughput assay systems
Custom diagnostic reagent platforms
Protein and Biomolecule Applications
MEP30UM-10 may also be evaluated for:
Immunoprecipitation
Protein enrichment
Protein-complex isolation
Enzyme immobilization
Affinity ligand preparation
Biomolecule capture
Biosensor development
Custom magnetic purification
Suitable Coupling Molecules
The epoxy-functional surface can be evaluated with:
Monoclonal antibodies
Polyclonal antibodies
Recombinant proteins
Antigens
Peptides
Enzymes
Lectins
Haptens
Other compatible ligands
Final coupling efficiency depends on ligand purity, concentration, accessible functional groups and reaction conditions.
General Coupling Workflow
1. Resuspend the Beads
Mix the suspension thoroughly before sampling to obtain a uniform bead concentration.
2. Wash the Magnetic Beads
Collect the beads with a magnetic separator and replace the storage solution with a suitable coupling buffer.
3. Add the Ligand
Add the purified antibody, antigen, protein or enzyme to the washed beads.
4. Perform Covalent Coupling
Incubate the bead–ligand mixture under optimized buffer, temperature and mixing conditions.
5. Block Residual Epoxy Groups
Deactivate remaining reactive groups with a suitable blocking reagent.
6. Wash the Coupled Beads
Remove unbound biomolecules and reaction components through repeated magnetic washing.
7. Resuspend and Evaluate
Resuspend the functionalized beads in the selected storage or assay buffer and evaluate assay performance.
Factors Affecting Coupling Efficiency
Important optimization factors include:
Ligand purity
Ligand concentration
Bead-to-ligand ratio
Coupling-buffer composition
Buffer pH
Ionic strength
Reaction temperature
Incubation time
Mixing efficiency
Blocking conditions
Small-scale optimization is recommended before bulk production.
Immunoassay Development Tips
Use purified antibodies or antigens.
Avoid unnecessary carrier proteins.
Confirm buffer and preservative compatibility.
Keep the 30 μm beads uniformly suspended.
Optimize ligand loading for signal and background.
Block residual epoxy groups after coupling.
Evaluate nonspecific binding.
Confirm magnetic separation performance.
Test coupled-bead storage stability.
Verify batch-to-batch assay consistency.
Bulk Production Quality Control
For research-to-production scale-up, evaluate:
Particle-size consistency
Suspension uniformity
Solid-content consistency
Magnetic collection performance
Coupling efficiency
Ligand loading
Nonspecific binding
Signal-to-background ratio
Assay sensitivity
Storage stability
Batch reproducibility
Epoxy vs. Carboxyl Magnetic Beads
Feature | Epoxy Magnetic Beads | Carboxyl Magnetic Beads |
|---|---|---|
Surface Group | Epoxy | Carboxyl |
Typical Activation | No additional activation normally required | EDC/NHS activation commonly used |
Coupling Targets | Compatible amino- or thiol-containing ligands | Mainly amino-containing ligands |
Workflow | Direct covalent coupling | Activation followed by coupling |
Main Advantage | Simplified immobilization | Flexible activation conditions |
Typical Use | Custom antibody and protein beads | Immunoassay ligand coupling |
The preferred surface chemistry depends on the ligand, coupling conditions and final assay requirements.
MEP30UM-10 vs. Passive Adsorption Beads
Feature | MEP30UM-10 Epoxy Beads | Passive Adsorption Beads |
|---|---|---|
Immobilization | Covalent coupling | Physical adsorption |
Ligand Retention | Stable attachment | Depends on adsorption stability |
Surface | Reactive epoxy groups | Non-reactive polymer surface |
Washing Resistance | Suitable for repeated washing | Ligand loss may occur |
Process Control | Controlled coupling conditions | Controlled by adsorption conditions |
Main Use | Customized functional beads | Simple protein coating |
Why Choose SHBC MEP30UM-10?
30 μm epoxy-functional magnetic beads
5% solid-content suspension
Suitable for immunoassay development
Flexible antibody and antigen coupling
Research and manufacturing quantities
Sample evaluation support
Stable batch supply
Bulk production capability
Custom packaging options
Technical support for product selection
Storage and Handling
Store MEP30UM-10 according to the product label and technical documentation.
Recommended handling practices:
Keep the container tightly sealed.
Mix thoroughly before use.
Avoid freezing unless validated.
Prevent microbial contamination.
Use clean pipettes and containers.
Avoid prolonged magnetic collection during storage.
Review the SDS before use.
Frequently Asked Questions
What is MEP30UM-10?
MEP30UM-10 is a 30 μm epoxy-functional magnetic bead suspension supplied at 5% solids.
What biomolecules can be coupled?
The beads can be evaluated for antibodies, antigens, proteins, peptides, enzymes and other compatible ligands.
Is EDC/NHS activation required?
No. The bead surface already contains reactive epoxy groups, so EDC/NHS activation is not normally required.
Can antibodies be coupled directly?
Yes. Compatible functional groups on purified antibodies can react with the epoxy-functional surface.
Can MEP30UM-10 be used for immunoassays?
Yes. It can be evaluated as a magnetic solid phase for antibody, antigen and biomarker-detection assays.
Why must the beads remain suspended?
The 30 μm beads may settle during incubation. Continuous or periodic mixing helps maintain consistent contact between the beads and ligand.
Why should residual epoxy groups be blocked?
Blocking deactivates unreacted surface groups and helps reduce unwanted downstream reactions.
Can the beads be used for protein purification?
Yes. After coupling a suitable affinity ligand, the beads can be evaluated for protein capture, enrichment and purification.
Are the beads suitable for automated systems?
The magnetic format can be evaluated in automated separation, washing and liquid-handling workflows.
Is coupling optimization necessary?
Yes. Ligand loading, buffer, pH, temperature, reaction time and blocking conditions should be optimized for each project.
Can SHBC supply bulk quantities?
Yes. SHBC supports sample evaluation, research supply and bulk production for immunoassay developers and reagent manufacturers.
Request MEP30UM-10 Samples
Contact Shanghai SanYu Biotechnology Co., Ltd. for MEP30UM-10 samples, technical documentation and bulk quotations.
Please provide:
Target antibody or antigen
Immunoassay format
Coupling scale
Required bead quantity
Current coupling method
Target application
Estimated annual demand
MEP30UM-10 is supplied for research and development. Final diagnostic applications must be validated by the customer.