 30um Epoxy Magnetic Beads MEP30UM-10 5%
MEP30UM-10 30 μm epoxy magnetic beads with 5% solids for covalent antibody and protein coupling, immunoassays, purification, and magnetic separation
  • MEP30UM-10

  • SHBC

  • 5%

  • 30µm

  • 10ml,20ml,50ml ,500ml,1000ml

Inquire

30 μm Epoxy Magnetic Beads MEP30UM-10

SHBC MEP30UM-10 Epoxy Magnetic Beads are 30 μm functional magnetic microspheres supplied at 5% solids.

The reactive epoxy surface supports covalent immobilization of antibodies, antigens, proteins, peptides, enzymes and other compatible biomolecules.

MEP30UM-10 is designed for immunoassay development, magnetic separation, biomolecule capture and scalable reagent production.

MEP30UM-10 Technical Specifications

Property

Specification

Product Name

Epoxy Magnetic Beads

Product Code

MEP30UM-10

Particle Size

30 μm

Surface Functionality

Epoxy

Solid Content

5%

Form

Aqueous Suspension

Main Function

Covalent Biomolecule Immobilization

Brand

SHBC

Manufacturer

Shanghai SanYu Biotechnology Co., Ltd.

Epoxy Coupling Principle

Epoxy groups on the bead surface can react with compatible amino or sulfhydryl groups in antibodies, proteins, peptides and enzymes.

This reaction creates stable covalent attachment between the biomolecule and magnetic bead surface. Additional EDC/NHS activation is normally unnecessary because reactive epoxy groups are already present.

After coupling, the beads can be magnetically collected, washed and resuspended for downstream applications.

Key Advantages of MEP30UM-10

  • Reactive epoxy-functional surface

  • 30 μm particle size

  • Supplied at 5% solids

  • Direct covalent ligand immobilization

  • Suitable for antibodies, antigens and proteins

  • Strong ligand retention during washing

  • Convenient magnetic separation

  • Easy buffer exchange

  • Flexible custom surface modification

  • Suitable for research and bulk production

Why Choose 30 μm Epoxy Magnetic Beads?

The larger 30 μm particle format supports convenient handling, magnetic collection and repeated washing.

MEP30UM-10 is suitable for workflows requiring:

  • Larger magnetic solid phases

  • Straightforward bead recovery

  • Custom antibody-coated beads

  • Custom antigen-coated beads

  • Manual magnetic separation

  • Automated magnetic washing

  • Scalable reagent preparation

Because larger beads may settle faster than smaller particles, uniform mixing is recommended during coupling and assay use.

Immunoassay Applications

Antibody-Coupled Magnetic Beads

Capture antibodies can be covalently immobilized on MEP30UM-10 for:

  • Sandwich immunoassays

  • Chemiluminescent immunoassays

  • Fluorescent immunoassays

  • Enzyme immunoassays

  • Magnetic immunoassays

  • Biomarker detection

  • Pathogen-detection research

The magnetic solid phase simplifies target capture, washing and separation.

Antigen-Coupled Magnetic Beads

Antigens can be immobilized for:

  • Antibody-detection assays

  • Serological research

  • Autoantibody assay development

  • Infectious-disease research

  • Assay calibration

  • Method validation

Automated Immunoassay Workflows

MEP30UM-10 can be evaluated in:

  • Automated chemiluminescence analyzers

  • Magnetic washing instruments

  • Liquid-handling platforms

  • High-throughput assay systems

  • Custom diagnostic reagent platforms

Protein and Biomolecule Applications

MEP30UM-10 may also be evaluated for:

  • Immunoprecipitation

  • Protein enrichment

  • Protein-complex isolation

  • Enzyme immobilization

  • Affinity ligand preparation

  • Biomolecule capture

  • Biosensor development

  • Custom magnetic purification

Suitable Coupling Molecules

The epoxy-functional surface can be evaluated with:

  • Monoclonal antibodies

  • Polyclonal antibodies

  • Recombinant proteins

  • Antigens

  • Peptides

  • Enzymes

  • Lectins

  • Haptens

  • Other compatible ligands

Final coupling efficiency depends on ligand purity, concentration, accessible functional groups and reaction conditions.

General Coupling Workflow

1. Resuspend the Beads

Mix the suspension thoroughly before sampling to obtain a uniform bead concentration.

2. Wash the Magnetic Beads

Collect the beads with a magnetic separator and replace the storage solution with a suitable coupling buffer.

3. Add the Ligand

Add the purified antibody, antigen, protein or enzyme to the washed beads.

4. Perform Covalent Coupling

Incubate the bead–ligand mixture under optimized buffer, temperature and mixing conditions.

5. Block Residual Epoxy Groups

Deactivate remaining reactive groups with a suitable blocking reagent.

6. Wash the Coupled Beads

Remove unbound biomolecules and reaction components through repeated magnetic washing.

7. Resuspend and Evaluate

Resuspend the functionalized beads in the selected storage or assay buffer and evaluate assay performance.

Factors Affecting Coupling Efficiency

Important optimization factors include:

  • Ligand purity

  • Ligand concentration

  • Bead-to-ligand ratio

  • Coupling-buffer composition

  • Buffer pH

  • Ionic strength

  • Reaction temperature

  • Incubation time

  • Mixing efficiency

  • Blocking conditions

Small-scale optimization is recommended before bulk production.

Immunoassay Development Tips

  • Use purified antibodies or antigens.

  • Avoid unnecessary carrier proteins.

  • Confirm buffer and preservative compatibility.

  • Keep the 30 μm beads uniformly suspended.

  • Optimize ligand loading for signal and background.

  • Block residual epoxy groups after coupling.

  • Evaluate nonspecific binding.

  • Confirm magnetic separation performance.

  • Test coupled-bead storage stability.

  • Verify batch-to-batch assay consistency.

Bulk Production Quality Control

For research-to-production scale-up, evaluate:

  • Particle-size consistency

  • Suspension uniformity

  • Solid-content consistency

  • Magnetic collection performance

  • Coupling efficiency

  • Ligand loading

  • Nonspecific binding

  • Signal-to-background ratio

  • Assay sensitivity

  • Storage stability

  • Batch reproducibility

Epoxy vs. Carboxyl Magnetic Beads

Feature

Epoxy Magnetic Beads

Carboxyl Magnetic Beads

Surface Group

Epoxy

Carboxyl

Typical Activation

No additional activation normally required

EDC/NHS activation commonly used

Coupling Targets

Compatible amino- or thiol-containing ligands

Mainly amino-containing ligands

Workflow

Direct covalent coupling

Activation followed by coupling

Main Advantage

Simplified immobilization

Flexible activation conditions

Typical Use

Custom antibody and protein beads

Immunoassay ligand coupling

The preferred surface chemistry depends on the ligand, coupling conditions and final assay requirements.

MEP30UM-10 vs. Passive Adsorption Beads

Feature

MEP30UM-10 Epoxy Beads

Passive Adsorption Beads

Immobilization

Covalent coupling

Physical adsorption

Ligand Retention

Stable attachment

Depends on adsorption stability

Surface

Reactive epoxy groups

Non-reactive polymer surface

Washing Resistance

Suitable for repeated washing

Ligand loss may occur

Process Control

Controlled coupling conditions

Controlled by adsorption conditions

Main Use

Customized functional beads

Simple protein coating

Why Choose SHBC MEP30UM-10?

  • 30 μm epoxy-functional magnetic beads

  • 5% solid-content suspension

  • Suitable for immunoassay development

  • Flexible antibody and antigen coupling

  • Research and manufacturing quantities

  • Sample evaluation support

  • Stable batch supply

  • Bulk production capability

  • Custom packaging options

  • Technical support for product selection

Storage and Handling

Store MEP30UM-10 according to the product label and technical documentation.

Recommended handling practices:

  • Keep the container tightly sealed.

  • Mix thoroughly before use.

  • Avoid freezing unless validated.

  • Prevent microbial contamination.

  • Use clean pipettes and containers.

  • Avoid prolonged magnetic collection during storage.

  • Review the SDS before use.

Frequently Asked Questions

What is MEP30UM-10?

MEP30UM-10 is a 30 μm epoxy-functional magnetic bead suspension supplied at 5% solids.

What biomolecules can be coupled?

The beads can be evaluated for antibodies, antigens, proteins, peptides, enzymes and other compatible ligands.

Is EDC/NHS activation required?

No. The bead surface already contains reactive epoxy groups, so EDC/NHS activation is not normally required.

Can antibodies be coupled directly?

Yes. Compatible functional groups on purified antibodies can react with the epoxy-functional surface.

Can MEP30UM-10 be used for immunoassays?

Yes. It can be evaluated as a magnetic solid phase for antibody, antigen and biomarker-detection assays.

Why must the beads remain suspended?

The 30 μm beads may settle during incubation. Continuous or periodic mixing helps maintain consistent contact between the beads and ligand.

Why should residual epoxy groups be blocked?

Blocking deactivates unreacted surface groups and helps reduce unwanted downstream reactions.

Can the beads be used for protein purification?

Yes. After coupling a suitable affinity ligand, the beads can be evaluated for protein capture, enrichment and purification.

Are the beads suitable for automated systems?

The magnetic format can be evaluated in automated separation, washing and liquid-handling workflows.

Is coupling optimization necessary?

Yes. Ligand loading, buffer, pH, temperature, reaction time and blocking conditions should be optimized for each project.

Can SHBC supply bulk quantities?

Yes. SHBC supports sample evaluation, research supply and bulk production for immunoassay developers and reagent manufacturers.

Request MEP30UM-10 Samples

Contact Shanghai SanYu Biotechnology Co., Ltd. for MEP30UM-10 samples, technical documentation and bulk quotations.

Please provide:

  • Target antibody or antigen

  • Immunoassay format

  • Coupling scale

  • Required bead quantity

  • Current coupling method

  • Target application

  • Estimated annual demand