Product Overview
SHBC Phenyl TopHIC FF (HS) is a high-resolution hydrophobic interaction chromatography (HIC) media designed for separation and purification of proteins and other biomolecules.
The media is based on 6% cross-linked agarose with an average particle size of approximately 34 μm and uses a Phenyl hydrophobic ligand.
Phenyl TopHIC FF (HS) provides approximately 36 mg/mL dynamic binding capacity for human serum albumin and is suitable for intermediate and fine purification where improved chromatographic resolution is required.
Key Features
34 μm average particle size
6% cross-linked agarose matrix
Phenyl hydrophobic ligand
HS specification
High-resolution HIC media
≈36 mg/mL dynamic binding capacity for Human Serum Albumin
Smaller particle size than conventional FF series
Suitable for intermediate purification
Suitable for fine purification
Designed for protein and biomolecule separation
Technical Specifications
Parameter | Specification |
|---|
Product Name | Phenyl TopHIC FF (HS) |
Brand | SHBC |
Product Type | High-Resolution Hydrophobic Interaction Chromatography Media |
Matrix | 6% Cross-Linked Agarose |
Ligand | Phenyl |
Specification | HS |
Chromatography Mode | Hydrophobic Interaction Chromatography |
Average Particle Size | 34 μm |
Dynamic Binding Capacity | ≈36 mg/mL (Human Serum Albumin) |
Package | 25 mL / 100 mL / 300 mL / 1 L / 5 L / 10 L / 20 L |
SHBC Art.No. | Packaging Specification |
A3036 | 25 mL |
A3037 | 100 mL |
A3038 | 300 mL |
A3039 | 1 L |
A3040 | 5 L |
A3041 | 10 L |
A3042 | 20 L |
34 μm High-Resolution Agarose Matrix
Phenyl TopHIC FF (HS) uses a 6% cross-linked agarose matrix with an average particle size of approximately 34 μm.
The smaller particle size provides enhanced chromatographic resolution and makes this series suitable for:
Intermediate purification
Fine purification
Polishing processes
High-resolution protein separation
Separation of biomolecules with different hydrophobic properties
Hydrophobic Interaction Chromatography
Hydrophobic interaction chromatography separates proteins and other biomolecules according to differences in their surface hydrophobicity.
Under appropriate high-salt conditions, hydrophobic regions of biomolecules interact with hydrophobic ligands immobilized on the chromatography matrix.
By gradually changing the mobile-phase conditions, the strength of these interactions can be reduced, allowing biomolecules with different hydrophobic characteristics to be separated.
Phenyl Hydrophobic Ligand
Phenyl TopHIC FF (HS) uses a Phenyl hydrophobic ligand.
Unlike alkyl ligands such as Butyl and Octyl, the Phenyl ligand contains an aromatic hydrophobic group and can provide different chromatographic selectivity.
This makes Phenyl HIC media useful for screening and purification processes where alternative hydrophobic selectivity is required.
HS Specification
This product is designated HS in the supplier table.
For this product, the specified reference dynamic binding capacity is:
≈36 mg/mL (Human Serum Albumin)
The table does not provide a separate definition for the abbreviation HS, so the product page retains the supplier's HS designation without expanding it into an unsupported technical meaning.
Dynamic Binding Capacity
Phenyl TopHIC FF (HS) provides a specified reference dynamic binding capacity of:
≈36 mg/mL for Human Serum Albumin
Actual binding performance may vary depending on the properties of the target biomolecule and chromatographic operating conditions.
High Resolution for Fine Purification
The series uses an average particle size of approximately 34 μm.
The smaller particle size provides higher chromatographic resolution and makes Phenyl TopHIC FF (HS) suitable when purification requires:
Applications
SHBC Phenyl TopHIC FF (HS) can be used for:
Protein purification
Recombinant protein purification
Biomolecule separation
Hydrophobic interaction chromatography
Intermediate purification
Fine purification
Polishing chromatography
Separation based on hydrophobicity
Biopharmaceutical downstream processing
Chromatography method development
Product Advantages
Phenyl TopHIC FF (HS) combines:
High chromatographic resolution
Fine 34 μm particle size
6% cross-linked agarose matrix
Phenyl hydrophobic selectivity
≈36 mg/mL Human Serum Albumin binding capacity
Suitable for intermediate purification
Suitable for fine purification
Suitable for protein and biomolecule separation
Phenyl, Butyl and Octyl HIC media use different hydrophobic ligands and therefore can provide different chromatographic selectivity.
Media | Ligand | Main Difference |
Phenyl TopHIC FF (HS) | Phenyl | Aromatic hydrophobic ligand |
Butyl TopHIC HP | Butyl | Butyl alkyl ligand |
Octyl TopHIC HP | Octyl | Octyl alkyl ligand |
The optimal HIC media should be selected according to the properties of the target biomolecule and the required separation performance.
Storage and Handling
Keep Phenyl TopHIC FF (HS) in its original container and protect the chromatography media from contamination during storage and handling.
Before use, equilibrate the packed bed with an appropriate buffer according to the intended HIC purification process.
Salt concentration, salt type, pH, sample loading and elution conditions should be optimized according to the target biomolecule.
Frequently Asked Questions
What is Phenyl TopHIC FF (HS)?
Phenyl TopHIC FF (HS) is a high-resolution hydrophobic interaction chromatography media using a Phenyl ligand.
What is the average particle size?
The average particle size is approximately 34 μm.
What matrix is used?
The media is based on 6% cross-linked agarose.
What ligand does Phenyl TopHIC FF (HS) use?
It uses a Phenyl hydrophobic ligand.
What is the dynamic binding capacity?
The specified dynamic binding capacity is approximately 36 mg/mL for Human Serum Albumin.
What does HS mean?
The supplied product table identifies this product as Phenyl TopHIC FF (HS) but does not provide a separate definition of HS. Therefore, HS is retained as the product specification designation.
Is Phenyl TopHIC FF (HS) suitable for fine purification?
Yes. The 34 μm high-resolution series is designed for intermediate and fine purification of biomolecules.
How does Phenyl HIC differ from Butyl or Octyl HIC?
Phenyl uses an aromatic hydrophobic ligand, while Butyl and Octyl use alkyl ligands. Different ligand chemistries can provide different chromatographic selectivity.
Typical applications include protein purification, biomolecule separation, intermediate purification, fine purification and HIC polishing.
What package sizes are available?
SHBC offers 25 mL, 100 mL, 300 mL, 1 L, 5 L, 10 L and 20 L packages.
What are the SHBC Art.No. numbers?
The corresponding SHBC Art.No. are A3036, A3037, A3038, A3039, A3040, A3041 and A3042.
What brand is Phenyl TopHIC FF (HS)?
Phenyl TopHIC FF (HS) is supplied under the SHBC brand.