Your Trusted Microsphere Manufacturer for Diagnostic Innovation

Products

SHBC provides colored microspheres, fluorescent microspheres, magnetic beads, silica microspheres, chromatography packing microspheres and biological reagents for diagnostic assay development, nucleic acid extraction, protein purification and separation applications.

Home Carboxyl Polystyrene Microspheres 400nm Carboxyl Green-Fluo Microspheres CFG400-10 1%
400nm Carboxyl Green-Fluo Microspheres CFG400-10 1%
400nm Carboxyl Green-Fluo Microspheres CFG400-10 1%
400nm Carboxyl Green-Fluo Microspheres CFG400-10 1%
400nm Carboxyl Green-Fluo Microspheres CFG400-10 1%
SHBC 400nm carboxyl green-fluo microspheres CFG400-10 offer bright green fluorescence and reactive COOH surfaces for LFIA, immunoassays, and biosensors.
  • CFG400-10

  • SHBC

  • 1%

  • 400nm

  • 10ml,20ml,50ml ,500ml,1000ml

Inquire

400nm Carboxyl Green-Fluo Microspheres CFG400-10

SHBC CFG400-10 Carboxyl Green-Fluo Microspheres are 400nm fluorescent polymer microspheres with surface carboxyl groups.

The microspheres provide green fluorescence with excitation at 470/488nm and emission at 525nm. A 1% solids suspension is supplied for fluorescence immunoassay development, quantitative lateral flow testing, biosensing and biomolecule conjugation.

Product Specifications

Item

Specification

Product Name

Carboxyl Green-Fluo Microspheres

Catalog Number

CFG400-10

Brand

SHBC

Particle Size

400nm

Solids Content

1%

Excitation Wavelength

470/488nm

Emission Wavelength

525nm

Fluorescence Color

Green

Surface Group

Carboxyl, COOH

Product Form

Microsphere Suspension

Manufacturer

Shanghai SanYu Biotechnology Co., Ltd.

Key Product Features

  • Bright green fluorescence at 525nm

  • Compatible with 470nm and 488nm excitation

  • Surface carboxyl groups for biomolecule coupling

  • Uniform 400nm particle size

  • Good suspension and dispersion performance

  • Stable fluorescent signal

  • Suitable for quantitative fluorescence detection

  • Available for research and batch production

Why Choose 400nm Green Fluorescent Microspheres?

The 400nm particle size provides a practical balance between fluorescent signal intensity, available coupling surface and membrane migration performance.

CFG400-10 is suitable for developing fluorescent probes that require stronger optical signals than smaller nanoparticles while maintaining good dispersion and assay compatibility.

Carboxyl Surface for Biomolecule Coupling

The microsphere surface contains carboxyl functional groups that can be activated for covalent conjugation with primary amine-containing biomolecules.

Compatible biomolecules include:

  • Antibodies

  • Antigens

  • Proteins

  • Peptides

  • Enzymes

  • Oligonucleotides

  • Other amine-containing ligands

EDC/NHS chemistry can be used to form stable amide bonds between the microspheres and target biomolecules.

Applications

Quantitative Lateral Flow Immunoassays

CFG400-10 can be used as a fluorescent reporter particle in quantitative lateral flow assays for detecting proteins, antibodies, antigens and other biomarkers.

Fluorescence Immunoassays

The microspheres provide a strong green fluorescent signal for sandwich immunoassays, competitive assays and fluorescence-based detection systems.

Point-of-Care Test Development

The 470/488nm excitation and 525nm emission profile is compatible with commonly used green fluorescence detection modules in POCT readers.

Antibody and Protein Conjugation

Surface carboxyl groups support covalent immobilization of antibodies, proteins and other biological ligands for stable fluorescent probe preparation.

Biosensors and Biochips

The microspheres can be used as fluorescent signal carriers in biosensors, microarrays, biochips and surface-based detection platforms.

Particle Tracing and Imaging

Their green fluorescence makes the microspheres suitable for fluorescence microscopy, particle tracking, transport studies and material distribution research.

Advantages for Fluorescent Assay Development

  • Strong fluorescence improves signal recognition

  • Carboxyl groups support stable covalent coupling

  • Uniform particles improve assay reproducibility

  • Good dispersibility supports consistent membrane migration

  • 488nm excitation is compatible with common optical systems

  • Suitable for qualitative and quantitative detection

  • Scalable supply supports product development and manufacturing

A typical EDC/NHS coupling procedure includes:

  1. Disperse the microsphere suspension thoroughly.

  2. Wash the microspheres with an appropriate activation buffer.

  3. Activate the surface carboxyl groups using EDC and NHS.

  4. Add the antibody, protein or other amine-containing biomolecule.

  5. Incubate under optimized reaction conditions.

  6. Block the remaining active sites.

  7. Wash and resuspend the conjugated microspheres.

  8. Evaluate fluorescence, coupling efficiency and assay performance.

Coupling conditions should be optimized according to the biomolecule, buffer system and final application.

  • Mix thoroughly before use.

  • Avoid prolonged high-power ultrasonication.

  • Protect the suspension from strong light.

  • Do not allow the microspheres to dry.

  • Avoid repeated freezing and thawing.

  • Use clean, low-binding laboratory consumables.

  • Confirm buffer compatibility before large-scale conjugation.

Quality and Batch Supply

SHBC supports fluorescent microsphere projects from early-stage assay development to batch production.

Available services include:

  • Different particle sizes

  • Different surface functional groups

  • Fluorescence wavelength customization

  • Solids-content adjustment

  • Surface carboxyl density optimization

  • Custom packaging

  • OEM and ODM production

  • Research samples and bulk supply

Why Choose SHBC?

Shanghai SanYu Biotechnology Co., Ltd. specializes in functional microspheres and magnetic beads for immunoassays, lateral flow tests, fluorescence detection and bioseparation.

SHBC provides:

  • Controlled particle-size production

  • Stable fluorescence performance

  • Functional surface modification

  • Reliable batch-to-batch consistency

  • Technical support for biomolecule coupling

  • Flexible packaging and bulk manufacturing

  • Custom microsphere development

Frequently Asked Questions

What is CFG400-10?

CFG400-10 is a 400nm carboxyl-functionalized green fluorescent microsphere suspension with 1% solids content.

What are the excitation and emission wavelengths?

The recommended excitation wavelengths are 470nm and 488nm. The emission wavelength is 525nm.

Can CFG400-10 be coupled with antibodies?

Yes. The surface carboxyl groups can be activated using EDC/NHS chemistry for covalent coupling with antibody amino groups.

Is CFG400-10 suitable for lateral flow assays?

Yes. It is designed for fluorescent lateral flow immunoassay development, including qualitative and quantitative detection.

What detection equipment can be used?

The microspheres can be detected using compatible fluorescence readers, fluorescence microscopes and optical systems equipped with suitable 470nm or 488nm excitation and 525nm emission filters.

Can SHBC provide bulk quantities?

Yes. SHBC supports laboratory samples, pilot-scale evaluation and bulk production for research institutions, diagnostic developers and reagent manufacturers.

Can the particle size or fluorescence wavelength be customized?

Yes. Particle size, fluorescence wavelength, surface functional group, solids content and packaging can be customized according to project requirements.

Ordering Information

Product: 400nm Carboxyl Green-Fluo Microspheres
Catalog Number: CFG400-10
Solids Content: 1%
Excitation: 470/488nm
Emission: 525nm
Brand: SHBC
Manufacturer: Shanghai SanYu Biotechnology Co., Ltd.

Contact SHBC for samples, technical specifications, customization and bulk production quotations.

For research and manufacturing use. Performance in final diagnostic products should be validated by the customer.

Related Products

    No content

Related Blogs

    No content