SHBC CFG500-10 500nm carboxyl green fluorescent microspheres, 1% solids, with 470/488nm excitation and 525nm emission for immunoassays and biosensing.
  • CFG500-10

  • SHBC

  • 1%

  • 500nm

  • 10ml,20ml,50ml ,500ml,1000ml

Inquire

500nm Carboxyl Green-Fluo Microspheres CFG500-10

SHBC CFG500-10 Carboxyl Green-Fluo Microspheres are 500nm fluorescent polymer microspheres with carboxyl-functionalized surfaces.

The microspheres provide bright green fluorescence with excitation at 470/488nm and emission at 525nm. They are supplied as a 1% solids suspension for fluorescent immunoassays, quantitative lateral flow tests, biosensors and biomolecule conjugation.

Product Specifications

Item

Specification

Product Name

Carboxyl Green-Fluo Microspheres

Catalog Number

CFG500-10

Brand

SHBC

Particle Size

500nm / 0.5μm

Solids Content

1%

Excitation Wavelength

470/488nm

Emission Wavelength

525nm

Fluorescence Color

Green

Surface Functional Group

Carboxyl, COOH

Product Form

Microsphere Suspension

Manufacturer

Shanghai SanYu Biotechnology Co., Ltd.

Key Features

  • Bright green fluorescent signal

  • Compatible with 470nm and 488nm excitation

  • Strong emission at 525nm

  • Carboxyl surface for covalent biomolecule coupling

  • Uniform 500nm particle size

  • Good suspension and dispersion performance

  • Suitable for qualitative and quantitative assays

  • Available for research and batch production

Why Choose 500nm Green Fluorescent Microspheres?

The 500nm particle size provides a large fluorescent signal carrier and sufficient surface area for biomolecule immobilization.

CFG500-10 is suitable for assay systems requiring:

  • Strong fluorescent signal output

  • Stable antibody or protein conjugation

  • Reliable particle recognition

  • Consistent quantitative detection

  • Good compatibility with fluorescence readers

The 0.5μm particle size is particularly useful for fluorescent lateral flow assays, biosensors and fluorescence-based particle detection.

Carboxyl Surface for Covalent Coupling

CFG500-10 contains carboxyl groups on the microsphere surface. These groups can be activated for covalent conjugation with primary amine-containing biomolecules.

Compatible ligands include:

  • Antibodies

  • Antigens

  • Proteins

  • Peptides

  • Enzymes

  • Oligonucleotides

  • Other amine-containing molecules

EDC/NHS chemistry can be used to form stable amide bonds between the microspheres and the target biomolecule.

Main Applications

Quantitative Lateral Flow Immunoassays

CFG500-10 can be used as a fluorescent reporter particle in quantitative lateral flow immunoassays.

The bright 525nm emission supports sensitive signal detection using compatible fluorescence readers.

Fluorescence Immunoassays

The microspheres are suitable for sandwich immunoassays, competitive immunoassays and other fluorescence-based detection platforms.

Applications include the detection of:

  • Proteins

  • Antibodies

  • Antigens

  • Hormones

  • Pathogen biomarkers

  • Inflammatory markers

  • Other biological analytes

Point-of-Care Test Development

The 470/488nm excitation profile is compatible with commonly used green fluorescence optical modules.

CFG500-10 can be evaluated for portable fluorescence readers and point-of-care testing systems.

Antibody and Protein Conjugation

The carboxyl-functionalized surface supports stable covalent immobilization of antibodies, proteins and peptides.

It can be used to prepare fluorescent probes for target capture, recognition and signal amplification.

Biosensors and Biochips

CFG500-10 can serve as a fluorescent signal carrier in:

  • Biosensors

  • Microarrays

  • Biochips

  • Microfluidic systems

  • Surface-based detection platforms

  • Multiplex detection research

Flow Cytometry and Fluorescence Imaging

The microspheres can be evaluated for fluorescence instrument calibration, particle tracking, fluorescence microscopy and flow-based particle analysis.

Cell and Particle Tracking

The green fluorescent signal allows the microspheres to be detected using suitable optical equipment.

They may be used in particle transport, material distribution, cell uptake and tracing studies.

Advantages for Assay Development

Strong Fluorescent Signal

The 500nm particle size can carry a strong fluorescence signal for optical detection and quantitative analysis.

Stable Covalent Conjugation

Surface carboxyl groups enable covalent coupling with amino-containing biomolecules through established activation chemistry.

Good Assay Reproducibility

Controlled particle size and consistent fluorescence help improve test repeatability and batch comparison.

Flexible Platform Compatibility

The 470/488nm excitation and 525nm emission profile is suitable for many green fluorescence detection systems.

Research-to-Production Supply

SHBC supports product evaluation, formulation development, pilot-scale testing and batch manufacturing.

A typical EDC/NHS coupling process includes:

  1. Mix the microsphere suspension thoroughly.

  2. Wash the microspheres with a suitable activation buffer.

  3. Activate the surface carboxyl groups using EDC and NHS.

  4. Add the antibody, protein or other amine-containing ligand.

  5. Incubate under optimized reaction conditions.

  6. Block the remaining active sites.

  7. Wash the conjugated microspheres.

  8. Resuspend the microspheres in a suitable storage buffer.

  9. Evaluate coupling efficiency and assay performance.

The reagent concentration, pH, reaction time and blocking conditions should be optimized for each biomolecule and application.

Handling Recommendations

  • Mix thoroughly before sampling.

  • Protect the product from strong light.

  • Avoid prolonged high-power ultrasonication.

  • Prevent the microspheres from drying.

  • Avoid repeated freezing and thawing.

  • Use clean and low-binding laboratory consumables.

  • Verify buffer compatibility before large-scale coupling.

  • Follow the product label and batch documentation for storage requirements.

Customization and Bulk Supply

Shanghai SanYu Biotechnology Co., Ltd. provides fluorescent microspheres for research institutions, diagnostic developers and reagent manufacturers.

Available customization services include:

  • Different particle sizes

  • Different fluorescence wavelengths

  • Carboxyl density adjustment

  • Alternative surface functional groups

  • Solids-content adjustment

  • Buffer formulation

  • Custom packaging

  • OEM and ODM production

  • Pilot-scale and bulk manufacturing

Why Choose SHBC?

SHBC specializes in functional microspheres and magnetic beads for immunoassays, lateral flow diagnostics, fluorescence detection and bioseparation.

Our advantages include:

  • Controlled particle-size production

  • Stable fluorescence performance

  • Functional surface modification

  • Reliable batch-to-batch consistency

  • Technical support for biomolecule coupling

  • Flexible packaging options

  • Research samples and bulk quantities

  • Custom microsphere development

Frequently Asked Questions

What is CFG500-10?

CFG500-10 is a 500nm carboxyl-functionalized green fluorescent microsphere suspension with 1% solids content.

What are its excitation and emission wavelengths?

The recommended excitation wavelengths are 470nm and 488nm. The emission wavelength is 525nm.

Can CFG500-10 be coupled with antibodies?

Yes. Its surface carboxyl groups can be activated using EDC/NHS chemistry for covalent antibody conjugation.

Is CFG500-10 suitable for lateral flow assays?

Yes. It can be evaluated as a fluorescent reporter particle for qualitative and quantitative lateral flow immunoassays.

What is the difference between 500nm and smaller fluorescent microspheres?

The 500nm particles provide a larger fluorescent carrier and more surface area per particle. Final sensitivity and membrane migration should be optimized according to the assay design.

What equipment can detect these microspheres?

They can be detected using compatible fluorescence readers, fluorescence microscopes and optical systems equipped with suitable excitation and emission filters.

Can SHBC provide samples?

Yes. Samples are available for coupling evaluation, formulation development and assay optimization.

Is bulk production available?

Yes. SHBC supports pilot-scale orders and bulk manufacturing for diagnostic reagent developers and industrial customers.

Can SHBC customize the particle size or wavelength?

Yes. Particle size, fluorescence wavelength, surface functional group, solids content, buffer and packaging can be customized.

Ordering Information

Product Name: 500nm Carboxyl Green-Fluo Microspheres
Catalog Number: CFG500-10
Particle Size: 500nm / 0.5μm
Solids Content: 1%
Excitation Wavelength: 470/488nm
Emission Wavelength: 525nm
Surface Group: Carboxyl, COOH
Brand: SHBC
Manufacturer: Shanghai SanYu Biotechnology Co., Ltd.