Your Trusted Microsphere Manufacturer for Diagnostic Innovation

Products

SHBC provides colored microspheres, fluorescent microspheres, magnetic beads, silica microspheres, chromatography packing microspheres and biological reagents for diagnostic assay development, nucleic acid extraction, protein purification and separation applications.

Home Carboxyl Polystyrene Microspheres 500nm Carboxyl Red-Fluo MicrospheresCFR500-10
500nm Carboxyl Red-Fluo MicrospheresCFR500-10
500nm Carboxyl Red-Fluo MicrospheresCFR500-10
SHBC 500nm carboxyl red-fluo microspheres CFR500-10 offer bright red fluorescence, uniform size, and reactive COOH surfaces for immunoassay and lateral flow.
  • CFR500-10

  • SHBC

  • 500nm

  • 10ml,20ml,50ml,100ml,1000ml

Inquire

500nm Carboxyl Red-Fluo Microspheres CFR500-10

SHBC CFR500-10 are 500 nm carboxyl-functionalized red fluorescent microspheres developed for fluorescent lateral flow assays, immunoassays and biomolecule labeling.

The microspheres feature excitation at 535 nm, emission at 610 nm and a 1% solid content. Surface carboxyl groups support covalent coupling with antibodies, antigens, proteins and other amino-containing biomolecules.

Product Specifications

Parameter

Specification

Product Name

Carboxyl Red-Fluo Microspheres

Catalog Number

CFR500-10

Nominal Particle Size

500 nm

Solid Content

1%

Surface Group

Carboxyl, COOH

Excitation Wavelength

535 nm

Emission Wavelength

610 nm

Fluorescence Color

Red

Supply Form

Aqueous Suspension

Brand

SHBC

Manufacturer

Shanghai SanYu Biotechnology Co., Ltd.

Batch-specific particle size, size distribution, carboxyl content and fluorescence data are available in the Certificate of Analysis.

Red Fluorescence at 535/610nm

CFR500-10 can be excited at approximately 535 nm and produces red fluorescence centered at approximately 610 nm.

The fluorescence profile is suitable for compatible fluorescence readers, imaging systems and quantitative immunoassay platforms.

Key Advantages

Bright Red Fluorescent Signal

The 535/610 nm optical profile provides a clear red signal for qualitative and quantitative detection.

500nm Particle Size

The 500 nm particle size provides a large fluorescent particle surface for biomolecule immobilization and signal generation.

Reactive Carboxyl Surface

Surface COOH groups support covalent coupling of antibodies, antigens, proteins, peptides and other amino-containing molecules.

Uniform Particle Size

Controlled particle sizing supports repeatable conjugation, membrane migration and assay performance.

1% Aqueous Suspension

The supplied suspension is convenient for laboratory evaluation, coupling development and production scale-up.

Custom and Bulk Supply

SHBC supports samples, customized specifications, pilot production and industrial batch supply.

Main Applications

Fluorescent Lateral Flow Immunoassays

CFR500-10 can be used as a fluorescent reporter particle in qualitative and quantitative lateral flow test strips.

Fluorescence Immunoassays

Suitable for sandwich, competitive and indirect fluorescent immunoassay formats.

Antibody Conjugation

The carboxyl surface supports stable covalent immobilization of antibodies used for target recognition.

Antigen and Protein Coupling

Suitable for coupling antigens, recombinant proteins, enzymes, peptides and other amino-containing biomolecules.

Infectious Disease Testing

Can be evaluated in fluorescent assays for viral, bacterial and other infectious disease biomarkers.

Cardiac and Inflammation Biomarkers

Suitable for assay development involving cardiac markers, inflammatory proteins and low-concentration analytes.

Food and Veterinary Testing

Can be used in fluorescent detection systems for food safety, veterinary diagnostics and agricultural testing.

Fluorescent Tracing

Suitable for selected membrane-flow, filtration, particle-transport and imaging studies.

Advantages in Lateral Flow Assays

CFR500-10 provides:

  • Bright red fluorescence

  • High signal per particle

  • Active COOH coupling surface

  • Compatibility with quantitative readers

  • Stable biomolecule immobilization

  • Suitable size for high-signal test development

  • Potential for multiplex detection

  • Support for research and batch production

Because 500 nm particles are relatively large for membrane-based assays, membrane pore structure, buffer composition and conjugate release should be optimized.

Biomolecule Coupling

Surface carboxyl groups can be activated using EDC/NHS chemistry and coupled with primary amine groups on antibodies or proteins.

A typical workflow includes:

  1. Wash and disperse the microspheres.

  2. Activate the carboxyl groups with EDC and NHS.

  3. Add the antibody or target protein.

  4. Block remaining active sites.

  5. Wash and resuspend the conjugate.

  6. Evaluate coupling efficiency and assay performance.

Activation pH, protein concentration, reaction time and blocking conditions should be optimized for each biomolecule.

Assay Development Considerations

Important parameters include:

  • Antibody-to-particle ratio

  • EDC and NHS concentration

  • Activation buffer and pH

  • Coupling time

  • Blocking reagent

  • Storage buffer

  • Membrane pore structure

  • Conjugate pad treatment

  • Running buffer composition

  • Reader filter settings

Optimization is recommended before production scale-up.

Membrane Flow Optimization

The 500 nm particle size can provide strong fluorescence but may migrate more slowly than smaller fluorescent particles.

Evaluate:

  • Nitrocellulose membrane type

  • Membrane pore structure

  • Particle aggregation

  • Sample viscosity

  • Surfactant concentration

  • Salt concentration

  • Conjugate pad release

  • Test-line capture density

  • Background fluorescence

  • Assay running time

Uniform dispersion is important for stable membrane migration and low background.

Dispersion and Handling

Before use:

  • Mix by gentle inversion or controlled vortexing

  • Avoid excessive bubbles and foam

  • Prevent the microspheres from drying

  • Protect the product from strong light

  • Avoid repeated freeze-thaw cycles

  • Confirm buffer compatibility

  • Redisperse settled particles before sampling

Controlled bath sonication may be used when necessary to redisperse the microspheres.

Custom Carboxyl Fluorescent Microspheres

SHBC can customize fluorescent microspheres according to assay requirements.

Customization options may include:

  • Custom particle size

  • Custom excitation and emission wavelengths

  • Different fluorescence colors

  • Carboxyl group density

  • Solid content

  • Dispersion buffer

  • Surface modification

  • Custom concentration

  • Custom packaging

  • OEM and ODM production

Please provide the target application, required wavelength, particle size and estimated quantity when requesting customization.

Quality Control and Documents

Available product documents may include:

  • Certificate of Analysis

  • Technical Data Sheet

  • Safety Data Sheet

  • Particle size report

  • Particle size distribution data

  • Fluorescence spectrum

  • Carboxyl content data

  • Microscopy images

  • Batch inspection report

Why Choose SHBC?

Shanghai SanYu Biotechnology Co., Ltd. supplies fluorescent microspheres, colored latex particles, magnetic beads and functional microsphere materials.

SHBC provides:

  • Controlled microsphere manufacturing

  • Stable particle size distribution

  • Multiple fluorescence wavelengths

  • Functional surface modification

  • Batch-to-batch consistency

  • Sample evaluation support

  • Pilot and bulk production

  • OEM and ODM services

Frequently Asked Questions

What is CFR500-10?

CFR500-10 is a 500 nm carboxyl-functionalized red fluorescent microsphere suspension with 1% solid content.

What are the excitation and emission wavelengths?

The excitation wavelength is 535 nm and the emission wavelength is 610 nm.

Is CFR500-10 suitable for lateral flow assays?

Yes. It can be evaluated as a fluorescent reporter in qualitative and quantitative lateral flow immunoassays.

What can be coupled to CFR500-10?

Antibodies, antigens, proteins, peptides and other molecules containing primary amine groups can be coupled to the carboxyl surface.

EDC/NHS chemistry is commonly used to activate carboxyl groups for covalent protein coupling.

What is the difference between 400nm and 500nm particles?

The 500 nm particles may provide higher signal per particle and more coupling surface, while the 400 nm particles may provide faster membrane migration. Actual performance should be compared in the final assay.

Can a 488nm laser excite CFR500-10?

The specified excitation wavelength is 535 nm. A 488 nm light source may produce weaker excitation and should be tested with the actual instrument.

How should CFR500-10 be dispersed?

Use gentle inversion, controlled vortexing or compatible bath sonication while avoiding excessive foam and aggregation.

Can CFR500-10 be customized?

Yes. Particle size, fluorescence wavelength, carboxyl density, solid content, buffer and packaging can be customized.

Are samples and bulk quantities available?

Yes. SHBC supports laboratory samples, pilot orders and industrial batch production.

Request a Sample or Quotation

Contact SHBC for CFR500-10 samples, technical specifications, coupling support and bulk pricing.

Please provide:

  • Target application

  • Target biomarker

  • Assay format

  • Required quantity

  • Preferred packaging

  • Estimated annual demand

Product: 500nm Carboxyl Red-Fluo Microspheres
Catalog Number: CFR500-10
Particle Size: 500 nm
Solid Content: 1%
Excitation/Emission: 535/610 nm
Surface Group: Carboxyl, COOH
Brand: SHBC
Manufacturer: Shanghai SanYu Biotechnology Co., Ltd.