Your Trusted Microsphere Manufacturer for Diagnostic Innovation

Products

SHBC provides colored microspheres, fluorescent microspheres, magnetic beads, silica microspheres, chromatography packing microspheres and biological reagents for diagnostic assay development, nucleic acid extraction, protein purification and separation applications.

Home Magnetic Beads 3 Um Epoxy Magnetic Beads MEP3UM-10 5%
3 Um Epoxy Magnetic Beads MEP3UM-10 5%
3 Um Epoxy Magnetic Beads MEP3UM-10 5%
MEP3UM-10 3 μm epoxy magnetic beads with 5% solids for covalent biomolecule coupling, immunoassays, protein purification, and magnetic separation.
  • MEP3UM-10

  • SHBC

  • 5%

  • 3µm

  • 10ml,20ml,50ml ,500ml,1000ml

Inquire

3 μm Epoxy Magnetic Beads MEP3UM-10

SHBC MEP3UM-10 Epoxy Magnetic Beads are 3 μm magnetic microspheres with reactive epoxy groups for the covalent immobilization of antibodies, antigens, proteins, peptides and enzymes.

Supplied at 5% solids, these beads are designed for immunoassay development, magnetic separation, protein research and scalable reagent production.

MEP3UM-10 Technical Specifications

Property

Specification

Product Name

Epoxy Magnetic Beads

Product Code

MEP3UM-10

Particle Size

3 μm

Surface Functionality

Epoxy

Solid Content

5%

Form

Aqueous Suspension

Main Function

Covalent Biomolecule Immobilization

Brand

SHBC

Manufacturer

Shanghai SanYu Biotechnology Co., Ltd.

How Do Epoxy Magnetic Beads Work?

Epoxy groups on the bead surface can react with primary amino or sulfhydryl groups in biomolecules.

This allows antibodies, proteins, peptides and functional enzymes to be covalently immobilized without an additional surface-activation step.

After coupling, the magnetic beads can be separated, washed and resuspended using a magnetic separator.

Key Advantages of MEP3UM-10

  • Reactive epoxy-functional surface

  • Direct covalent ligand immobilization

  • 3 μm particle size for convenient magnetic handling

  • 5% solids for research and process development

  • Suitable for antibodies, antigens, proteins and enzymes

  • Helps improve ligand retention during repeated washing

  • Supports flexible custom magnetic-bead preparation

  • Suitable for manual and automated workflows

  • Scalable from assay development to bulk production

  • Applicable to immunoassay and protein-research projects

Why Use 3 μm Epoxy Magnetic Beads?

The 3 μm particle format provides a practical balance between available surface area, suspension handling and magnetic collection.

MEP3UM-10 is suitable for laboratories and reagent manufacturers requiring:

  • Easy magnetic separation

  • Stable assay solid phases

  • Flexible antibody or antigen coupling

  • Repeatable washing procedures

  • Scalable reagent preparation

  • Custom magnetic-particle development

Immunoassay Applications

Antibody-Coupled Magnetic Beads

Antibodies can be immobilized on the epoxy surface to prepare capture beads for:

  • Sandwich immunoassays

  • Chemiluminescent immunoassays

  • Fluorescent immunoassays

  • Enzyme immunoassays

  • Magnetic immunoassays

  • Biomarker detection

  • Pathogen detection research

Antigen-Coupled Magnetic Beads

Antigens can be coupled to the beads for:

  • Antibody detection assays

  • Serological research

  • Autoantibody testing development

  • Infectious-disease assay development

  • Assay calibration and validation

Automated Immunoassay Systems

Epoxy magnetic beads can serve as a magnetic solid phase for presenting antibodies or antigens in automated immunoassay workflows. Magnetic separation simplifies reaction, washing and collection steps.

Protein Research Applications

MEP3UM-10 can also be evaluated for:

  • Immunoprecipitation

  • Protein enrichment

  • Protein-complex isolation

  • Enzyme immobilization

  • Affinity ligand preparation

  • Biomolecule capture

  • Custom magnetic purification

  • Assay-development research

Covalently immobilized ligands can help reduce ligand release during washing and downstream separation.

Suitable Coupling Molecules

The epoxy-functional surface can be evaluated for coupling:

  • Monoclonal antibodies

  • Polyclonal antibodies

  • Recombinant proteins

  • Antigens

  • Peptides

  • Enzymes

  • Lectins

  • Other compatible affinity ligands

The final coupling result depends on ligand purity, functional groups, concentration and reaction conditions.

General Coupling Workflow

1. Resuspend the Beads

Mix the bead suspension thoroughly to obtain a uniform dispersion before sampling.

2. Wash the Magnetic Beads

Collect the beads with a magnetic separator and replace the storage solution with the selected coupling buffer.

3. Add the Ligand

Add the purified antibody, antigen, protein or enzyme to the washed beads.

4. Perform Covalent Coupling

Incubate under optimized conditions to allow the epoxy groups to react with compatible functional groups on the ligand.

5. Block Residual Reactive Groups

Deactivate remaining epoxy groups with a suitable blocking reagent after coupling.

6. Wash the Coupled Beads

Use magnetic separation to remove unbound ligand and reaction components.

7. Resuspend and Evaluate

Resuspend the coupled beads in the selected storage or assay buffer and evaluate coupling efficiency, magnetic response and assay performance.

Factors Affecting Coupling Efficiency

Coupling performance may be influenced by:

  • Ligand purity

  • Ligand concentration

  • Available amino or thiol groups

  • Buffer composition

  • Buffer pH

  • Ionic strength

  • Reaction temperature

  • Incubation time

  • Mixing efficiency

  • Bead-to-ligand ratio

  • Blocking conditions

Small-scale optimization is recommended before transferring the process to bulk production.

Tips for Immunoassay Development

For more consistent results:

  • Use purified antibodies or antigens.

  • Avoid carrier proteins that may compete with the target ligand.

  • Confirm that buffer additives are compatible with epoxy coupling.

  • Keep the beads uniformly suspended during reaction.

  • Optimize ligand loading instead of using excessive protein.

  • Block unreacted epoxy groups after coupling.

  • Evaluate nonspecific binding in the final assay buffer.

  • Confirm coupled-bead stability before production scale-up.

MEP3UM-10 vs. Passive Adsorption Beads

Feature

Epoxy Magnetic Beads

Passive Adsorption Beads

Immobilization Method

Covalent coupling

Physical adsorption

Ligand Retention

Stronger attachment

Depends on adsorption stability

Surface Activation

Epoxy groups are pre-functionalized

No reactive surface required

Coupling Control

Adjusted through reaction conditions

Adjusted through pH and hydrophobic interaction

Washing Resistance

Suitable for repeated washing

Ligand loss may occur

Main Use

Custom functional magnetic beads

Simple protein coating

MEP3UM-10 vs. Protein A/G Magnetic Beads

MEP3UM-10 provides direct covalent immobilization of selected ligands.

Protein A or Protein G beads capture antibodies through the Fc region and are mainly used for antibody purification or immunoprecipitation.

Choose epoxy magnetic beads when permanent custom ligand immobilization is required.

Why Choose SHBC MEP3UM-10?

  • 3 μm epoxy-functional magnetic beads

  • 5% solid-content suspension

  • Suitable for immunoassay research

  • Flexible antibody and antigen coupling

  • Support for custom formulation development

  • Sample testing available

  • Stable batch and bulk supply

  • Suitable for research and industrial scale-up

  • Technical communication for application selection

  • Manufactured by Shanghai SanYu Biotechnology Co., Ltd.

Quality Evaluation Recommendations

Before use in a production assay, evaluate:

  • Particle size consistency

  • Suspension uniformity

  • Magnetic separation time

  • Coupling efficiency

  • Ligand loading

  • Nonspecific binding

  • Signal-to-background ratio

  • Assay sensitivity

  • Coupled-bead stability

  • Batch-to-batch performance

Storage and Handling

Store MEP3UM-10 according to the product label and technical documentation.

Recommended handling practices include:

  • Keep the container tightly closed.

  • Avoid freezing unless specifically validated.

  • Mix thoroughly before use.

  • Prevent microbial contamination.

  • Use clean pipette tips and containers.

  • Avoid prolonged exposure to strong magnetic fields during storage.

  • Review the SDS before laboratory or industrial use.

Frequently Asked Questions

What is MEP3UM-10?

MEP3UM-10 is a 3 μm epoxy-functional magnetic bead suspension supplied at 5% solids.

What can be coupled to the beads?

The beads can be evaluated for covalent coupling of antibodies, antigens, proteins, peptides, enzymes and other compatible ligands.

Do the beads require EDC or NHS activation?

No additional EDC/NHS activation is normally required because the bead surface already contains reactive epoxy groups.

Can MEP3UM-10 be used for immunoassays?

Yes. It is designed for developing magnetic solid phases used in antibody, antigen and biomarker-detection assays.

Can antibodies be coupled directly?

Yes. Compatible amino or thiol groups on purified antibodies can react with the epoxy-functional surface.

Why is blocking required after coupling?

Blocking deactivates residual epoxy groups and helps reduce unwanted reactions during subsequent assay steps.

Can the beads be used for immunoprecipitation?

Yes. After coupling a suitable antibody, the beads can be evaluated for immunoprecipitation and protein enrichment.

Are the beads suitable for automated instruments?

The magnetic format can be evaluated in automated immunoassay, washing and liquid-handling workflows.

Is coupling optimization necessary?

Yes. Ligand type, concentration, pH, temperature, incubation time and blocking conditions should be optimized for each project.

Can SHBC supply bulk quantities?

Yes. SHBC supports sample evaluation, formulation development and bulk supply for research organizations and reagent manufacturers.

Request MEP3UM-10 Samples

Contact Shanghai SanYu Biotechnology Co., Ltd. for MEP3UM-10 samples, technical information and bulk quotations.

Please provide:

  • Target ligand

  • Immunoassay format

  • Coupling scale

  • Required bead quantity

  • Current coupling method

  • Target application

  • Estimated annual demand

Related Products

    No content

Related Blogs

    No content